Quality of Life with Defibrillator Therapy or Amiodarone in Heart Failure
- 4 September 2008
- journal article
- research article
- Published by Massachusetts Medical Society in The New England Journal of Medicine
- Vol. 359 (10), 999-1008
- https://doi.org/10.1056/nejmoa0706719
Abstract
Implantable cardioverter–defibrillator (ICD) therapy significantly prolongs life in patients at increased risk for sudden death from depressed left ventricular function. However, whether this increased longevity is accompanied by deterioration in the quality of life is unclear. In a randomized trial, we compared ICD therapy or amiodarone with state-of-the-art medical therapy alone in 2521 patients who had stable heart failure with depressed left ventricular function. We prospectively measured quality of life at baseline and at months 3, 12, and 30; data collection was 93 to 98% complete. The Duke Activity Status Index (which measures cardiac physical functioning) and the Medical Outcomes Study 36-Item Short-Form Mental Health Inventory 5 (which measures psychological well-being) were prespecified primary outcomes. Multiple additional quality-of-life outcomes were also examined. Psychological well-being in the ICD group, as compared with medical therapy alone, was significantly improved at 3 months (P=0.01) and at 12 months (P=0.003) but not at 30 months. No clinically or statistically significant differences in physical functioning among the study groups were observed. Additional quality-of-life measures were improved in the ICD group at 3 months, 12 months, or both, but there was no significant difference at 30 months. ICD shocks in the month preceding a scheduled assessment were associated with a decreased quality of life in multiple domains. The use of amiodarone had no significant effects on the primary quality-of-life outcomes. In a large primary-prevention population with moderately symptomatic heart failure, single-lead ICD therapy was not associated with any detectable adverse quality-of-life effects during 30 months of follow-up.Keywords
This publication has 15 references indexed in Scilit:
- An Estimator for Treatment Comparisons among Survivors in Randomized TrialsBiometrics, 2005
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureThe New England Journal of Medicine, 2005
- Quality of Life in the Antiarrhythmics Versus Implantable Defibrillators TrialCirculation, 2002
- Causal Inference Without CounterfactualsJournal of the American Statistical Association, 2000
- Prophylactic Use of Implanted Cardiac Defibrillators in Patients at High Risk for Ventricular Arrhythmias after Coronary-Artery Bypass Graft SurgeryThe New England Journal of Medicine, 1997
- Medical Care Costs and Quality of Life after Randomization to Coronary Angioplasty or Coronary Bypass SurgeryThe New England Journal of Medicine, 1997
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaThe New England Journal of Medicine, 1996
- Amiodarone in Patients with Congestive Heart Failure and Asymptomatic Ventricular ArrhythmiaThe New England Journal of Medicine, 1995
- Utilities and Quality-Adjusted Life YearsInternational Journal of Technology Assessment in Health Care, 1989
- A brief self-administered questionnaire to determine functional capacity (The Duke Activity Status Index)The American Journal of Cardiology, 1989