Bioabsorbable Miniplating Versus Metallic Fixation for Metacarpal Fractures
- 1 May 2003
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Clinical Orthopaedics and Related Research
- Vol. 410 (410), 310-319
- https://doi.org/10.1097/01.blo.0000063789.32430.c6
Abstract
Bioabsorbable implants offer an attractive alternative to metallic implants to stabilize small bone fractures in the hand. Self-reinforced bioabsorbable miniplating for metacarpal fractures was studied in bones from cadavers and compared with standard metallic fixation methods. One hundred twelve fresh-frozen metacarpals from humans had three-point bending and torsional loading after transverse osteotomy followed by fixation using seven methods: (1) dorsal and (2) dorsolateral 2-mm self-reinforced polylactide-polyglycolide 80/20 plating, (3) dorsal and (4) dorsolateral 2-mm self-reinforced poly-L/DL-lactide 70/30 plating, (5) dorsal 1.7-mm titanium plating, (6) dorsal 2.3-mm titanium plating, and (7) crossed 1.25-mm Kirschner wires. In apex dorsal and palmar bending, dorsal self-reinforced polylactide-polyglycolide and poly-L/DL-lactide plates provided stability comparable with dorsal titanium 1.7-mm plating. When the bioabsorbable plates were applied dorsolaterally, apex palmar rigidity was increased and apex dorsal rigidity was decreased. Bioabsorbable platings resulted in higher torsional rigidity than 1.7-mm titanium plating and in failure torque comparable with 2.3-mm titanium plating. Low-profile selfreinforced polylactide-polyglycolide and poly-L/DL-lactide miniplates provide satisfactory biomechanical stability for metacarpal fixation. These findings suggest that bioabsorbable miniplating can be used safely in the clinical stabilization of metacarpal and phalangeal fractures.Keywords
This publication has 26 references indexed in Scilit:
- Developments in Craniomaxillofacial Surgery: Use of Self-Reinforced Bioabsorbable Osteofixation DevicesPlastic and Reconstructive Surgery, 2001
- Mechanical testing of bioresorbable implants for use in metacarpal fracture fixationThe Journal of Hand Surgery, 2001
- FIXATION OF METACARPAL FRACTURES USING ABSORBABLE HEMI-CERCLAGE SUTURESJournal of Hand Surgery (European Volume), 1999
- Internal Fixation of Phalangeal Fractures Using Titanium MiniplatesAnnals of Plastic Surgery, 1999
- Biomechanical Properties of Absorbable Implants in Finger FracturesJournal of Hand Surgery (European Volume), 1998
- Internal fixation of metacarpal and phalangeal fractures with AO minifragment screws and plates: a prospective studyInjury, 1993
- Fractures of the metacarpals: Treatment by A. O. screw and plate fixationJournal of Hand Surgery (European Volume), 1987
- Fixation of metacarpal and phalangeal fractures with miniature plates and screwsThe Journal of Hand Surgery, 1986
- Comparison of internal fixation techniques in metacarpal fracturesThe Journal of Hand Surgery, 1985
- A biodegradable tendon gliding deviceThe Hand, 1975