Abstract
Computer-aided diagnosis (CAD) for colonoscopy may help endoscopists distinguish neoplastic polyps (adenomas) requiring resection from nonneoplastic polyps not requiring resection, potentially reducing cost. To evaluate the performance of real-time CAD with endocytoscopes (×520 ultramagnifying colonoscopes providing microvascular and cellular visualization of colorectal polyps after application of the narrow-band imaging [NBI] and methylene blue staining modes, respectively). Single-group, open-label, prospective study. (UMIN [University hospital Medical Information Network] Clinical Trial Registry: UMIN000027360). University hospital. 791 consecutive patients undergoing colonoscopy and 23 endoscopists. Real-time use of CAD during colonoscopy. CAD-predicted pathology (neoplastic or nonneoplastic) of detected diminutive polyps (≤5 mm) on the basis of real-time outputs compared with pathologic diagnosis of the resected specimen (gold standard). The primary end point was whether CAD with the stained mode produced a negative predictive value (NPV) of 90% or greater for identifying diminutive rectosigmoid adenomas, the threshold required to “diagnose-and-leave” nonneoplastic polyps. Best- and worst-case scenarios assumed that polyps lacking either CAD diagnosis or pathology were true- or false-positive or true- or false-negative, respectively. Overall, 466 diminutive (including 250 rectosigmoid) polyps from 325 patients were assessed by CAD, with a pathologic prediction rate of 98.1% (457 of 466). The NPVs of CAD for diminutive rectosigmoid adenomas were 96.4% (95% CI, 91.8% to 98.8%) (best-case scenario) and 93.7% (CI, 88.3% to 97.1%) (worst-case scenario) with stained mode and 96.5% (CI, 92.1% to 98.9%) (best-case scenario) and 95.2% (CI, 90.3% to 98.0%) (worst-case scenario) with NBI. Two thirds of the colonoscopies were conducted by experts who had each experienced more than 200 endocytoscopies; 186 polyps not assessed by CAD were excluded. Real-time CAD can achieve the performance level required for a diagnose-and-leave strategy for diminutive, nonneoplastic rectosigmoid polyps. Japan Society for the Promotion of Science.Keywords
This publication has 26 references indexed in Scilit:
- The addition of high magnifying endoscopy improves rates of high confidence optical diagnosis of colorectal polypsEndoscopy International Open, 2015
- Evidence-based clinical practice guidelines for management of colorectal polypsThe Esophagus, 2015
- Novel computer-aided diagnostic system for colorectal lesions by using endocytoscopy (with videos)Gastrointestinal Endoscopy, 2014
- Automatic optical diagnosis of small colorectal lesions by laser-induced autofluorescenceEndoscopy, 2014
- Long-Term Colorectal-Cancer Incidence and Mortality after Lower EndoscopyThe New England Journal of Medicine, 2013
- Real-Time Optical Biopsy of Colon Polyps With Narrow Band Imaging in Community Practice Does Not Yet Meet Key Thresholds for Clinical DecisionsGastroenterology, 2013
- Computer-based classification of small colorectal polyps by using narrow-band imaging with optical magnificationGastrointestinal Endoscopy, 2011
- The American Society for Gastrointestinal Endoscopy PIVI (Preservation and Incorporation of Valuable Endoscopic Innovations) on real-time endoscopic assessment of the histology of diminutive colorectal polypsGastrointestinal Endoscopy, 2011
- The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented researchGastrointestinal Endoscopy, 2009
- Competitive learning with floating-gate circuitsIEEE Transactions on Neural Networks, 2002