Improving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context
- 1 May 2009
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Anesthesia & Analgesia
- Vol. 108 (5), 1546-1552
- https://doi.org/10.1213/ane.0b013e31819bdfbb
Abstract
In an intensive care unit, alarms are used to call attention to a patient, to alert a change in the patient's physiology, or to warn of a failure in a medical device; however, up to 94% of the alarms are false. Our purpose in this study was to identify a means of reducing the number of false alarms. An observer recorded time-stamped information of alarms and the presence of health care team members in the patient room; each alarm response was classified as effective (action taken within 5 min), ineffective (no response to the alarm), and ignored (alarm consciously ignored or actively silenced). During the 200-h study period, 1271 separate entries by an individual to the room being observed were recorded, 1214 alarms occurred and 2344 tasks were performed. On average, alarms occurred 6.07 times per hour and were active for 3.28 min per hour; 23% were effective, 36% were ineffective, and 41% were ignored. The median alarm duration was 17 s. A 14-s delay before alarm presentation would remove 50% of the ignored and ineffective alarms, and a 19-s delay would remove 67%. Suctioning, washing, repositioning, and oral care caused 152 ignored or ineffective ventilator alarms. Introducing a 19-s alarm delay and automatically detecting suctioning, repositioning, oral care, and washing could reduce the number of ineffective and ignored alarms from 934 to 274. More reliable alarms could elicit more timely response, reduce workload, reduce noise pollution, and potentially improve patient safety.Keywords
This publication has 18 references indexed in Scilit:
- Noise levels in a general intensive care unit: a descriptive studyNursing in Critical Care, 2007
- Context awareness in health care: A reviewInternational Journal of Medical Informatics, 2007
- Alarm Algorithms in Critical Care MonitoringAnesthesia & Analgesia, 2006
- Noninvasive Measurement of Heartbeat, Respiration, Snoring and Body Movements of a Subject in Bed via a Pneumatic MethodIEEE Transactions on Biomedical Engineering, 2005
- A Comparison of the Failure Times of Pulse Oximeters During Blood Pressure Cuff-Induced Hypoperfusion in VolunteersAnesthesia & Analgesia, 2004
- SPECIAL SECTION: Adapting to New Technology in the Operating RoomHuman Factors: The Journal of the Human Factors and Ergonomics Society, 1996
- Are there too many alarms in the intensive care unit? An overview of the problemsJournal of Advanced Nursing, 1995
- Crying wolfCritical Care Medicine, 1994
- Frequency and reliability of alarms in the monitoring of cardiac postoperative patientsJournal of Clinical Monitoring and Computing, 1990
- Survey of alarms in an intensive therapy unit*Anaesthesia, 1986