Cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: an updated meta-analysis of randomized and observational studies
- 4 October 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (3), 378-384
- https://doi.org/10.1093/europace/euw262
Abstract
Radiofrequency (RF) ablation represents a standard of care for pulmonary vein isolation in patients with drug-refractory paroxysmal atrial fibrillation (AF). In this setting, cryoballoon (CB) ablation has emerged as alternative therapy. However, the efficacy and safety of CB vs. RF ablation in patients with paroxysmal AF remain a matter of debate. We searched electronic scientific databases for studies of CB vs. RF ablation in patients with paroxysmal AF. Aggregate data were pooled to perform a meta-analysis. The primary efficacy and safety outcomes were the recurrence of any atrial arrhythmia and procedure-related complications, respectively. A total of 6473 participants from 10 studies (CB, n = 2232 vs. RF, n = 4241) were studied. After a median follow-up of 16 months, the risk of any atrial arrhythmia recurrence (risk ratio, RR 95% confidence interval [95% CI] = 1.01 [0.90–1.14], P = 0.83) and procedure-related complications (RR [95% CI] = 0.92 [0.66–1.28], P = 0.61) were comparable between CB vs. RF ablation. Cryoballoon ablation led to a higher risk of persistent phrenic nerve palsy (RR [95% CI] = 13.60 [3.87–47.81], P < 0.01) and a lower risk of cardiac tamponade (RR [95% CI] = 0.48 [0.25–0.89], P = 0.02) compared with RF ablation. There was a trend of statistically significant interaction between the type of CB and the duration of ablation (P for interaction = 0.09). In patients with paroxysmal AF, ablation therapy with CB is associated with efficacy and safety comparable to that of RF. Second-generation CB catheters seem to reduce procedure duration. Further studies are warranted to disclose the impact of second-generation CB catheters compared with RF for ablation of paroxysmal AF.Keywords
This publication has 28 references indexed in Scilit:
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationThe New England Journal of Medicine, 2016
- First-line catheter ablation of paroxysmal atrial fibrillation: outcome of radiofrequency vs. cryoballoon pulmonary vein isolationEP Europace, 2015
- Cryoballoon Versus Open Irrigated Radiofrequency Ablation in Patients With Paroxysmal Atrial FibrillationCirculation, 2015
- 50 year trends in atrial fibrillation prevalence, incidence, risk factors, and mortality in the Framingham Heart Study: a cohort studyThe Lancet, 2015
- The COR trial: A randomized study with continuous rhythm monitoring to compare the efficacy of cryoenergy and radiofrequency for pulmonary vein isolationHeart Rhythm, 2014
- Cryoballoon versus RF Ablation in Paroxysmal Atrial Fibrillation: Results from the German Ablation RegistryJournal of Cardiovascular Electrophysiology, 2013
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEP Europace, 2012
- Measuring inconsistency in meta-analysesBMJ, 2003
- Impact of Atrial Fibrillation on the Risk of DeathCirculation, 1998
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsThe New England Journal of Medicine, 1998