Abstract
The recent clinical adoption of optical coherence tomography (OCT) angiography (OCTA) has enabled non-invasive, volumetric visualization of ocular vasculature at micron-scale resolutions. Initially limited to 3 mm × 3 mm and 6 mm × 6 mm fields-of-view (FOV), commercial OCTA systems now offer 12 mm × 12 mm, or larger, imaging fields. While larger FOVs promise a more complete visualization of retinal disease, they also introduce new challenges to the accurate and reliable interpretation of OCTA data. In particular, because of vignetting, wide-field imaging increases occurrence of low-OCT-signal artifacts, which leads to thresholding and/or segmentation artifacts, complicating OCTA analysis. This study presents theoretical and case-based descriptions of the causes and effects of low-OCT-signal artifacts. Through these descriptions, we demonstrate that OCTA data interpretation can be ambiguous if performed without consulting corresponding OCT data. Furthermore, using wide-field non-perfusion analysis in diabetic retinopathy as a model widefield OCTA usage-case, we show how qualitative and quantitative analysis can be confounded by low-OCT-signal artifacts. Based on these results, we suggest methods and best-practices for preventing and managing low-OCT-signal artifacts, thereby reducing errors in OCTA quantitative analysis of non-perfusion and improving reproducibility. These methods promise to be especially important for longitudinal studies detecting progression and response to therapy.Keywords
This publication has 30 references indexed in Scilit:
- IMAGE ARTIFACTS IN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHYRetina, 2015
- Diabetic Retinopathy Severity and Peripheral Lesions Are Associated with Nonperfusion on Ultrawide Field AngiographyOphthalmology, 2015
- Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eyeProceedings of the National Academy of Sciences of the United States of America, 2015
- Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angleBiomedical Optics Express, 2015
- Wide-field optical model of the human eye with asymmetrically tilted and decentered lens that reproduces measured ocular aberrationsOptica, 2015
- Megahertz ultra-wide-field swept-source retina optical coherence tomography compared to current existing imaging devicesAlbrecht von Graefes Archiv für Ophthalmologie, 2014
- Optic Disc Measurements in Myopia with Optical Coherence Tomography and Confocal Scanning Laser OphthalmoscopyPublished by Association for Research in Vision and Ophthalmology (ARVO) ,2007
- Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patientsJournal of Biomedical Optics, 2007
- Distribution of Capillary Nonperfusion in Early-stage Diabetic RetinopathyOphthalmology, 1984
- Midperipheral Fundus Involvement in Diabetic RetinopathyOphthalmology, 1981