Value of Power Doppler and Gray-Scale US in the Diagnosis of Carpal Tunnel Syndrome: Contribution of Cross-Sectional Area just before the Tunnel Inlet as Compared with the Cross-Sectional Area at the Tunnel
Open Access
- 1 January 2010
- journal article
- research article
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 11 (6), 632-639
- https://doi.org/10.3348/kjr.2010.11.6.632
Abstract
To determine the value of gray-scale and power Doppler ultrasonography in the evaluation of carpal tunnel syndrome (CTS). Median nerves at the carpal tunnel were evaluated by using gray-scale and power Doppler ultrasonography and by using accepted and new criteria in 42 patients with CTS (62 wrists) confirmed by electromyogram and 33 control subjects. We evaluated the cross-sectional area of the nerve just proximal to the tunnel inlet (CSAa), and at mid level (CSAb). We then calculated the percentage area increase of CSAb, and area difference (CSAb-CSAa). We measured two dimensions of the nerve at the distal level to calculate the flattening ratio. The power Doppler ultrasonography was used to assess the number of vessels, which proceeded to give a score according to the vessel number, and lastly evaluated the statistical significance by comparing the means of patients with control subjects by the Student t test for independent samples. Sensitivities and specificities were determined for sonographic characteristics mentioned above. We obtained the receiver operating characteristic (ROC) curve to assess the optimal cut-off values for the diagnosis of CTS. A statistically significant difference was found between patients and the control group for mean CSAb, area difference, percentage area increase, and flattening ratio (p < 0.001, p < 0.001, p < 0.001, p < 0.05, respectively). From the ROC curve we obtained optimal cut-off values of 11 mm2 for CSAb, 3.65 for area difference, 50% for the percentage of area increase, and 2.6 for the flattening ratio. The mean number of vessels obtained by power Doppler ultrasonography from the median nerve was 1.2. We could not detect vessels from healthy volunteers. Mean CSAbs related to vascularity intensity scores were as follows: score 0: 12.3 ± 2.8 mm2, score 1: 12.3 ± 3.1 mm2, score 2: 14.95 ± 3.5 mm2, score 3: 19.3 ± 3.8 mm2. The mean PI value in vessels of the median nerve was 4.1 ± 1. Gray-scale and power Doppler ultrasonography are useful in the evaluation of CTS.Keywords
This publication has 26 references indexed in Scilit:
- Ultrasound Diagnosis of Either an Occult or Missed Fracture of an Extremity in Pediatric-Aged ChildrenKorean Journal of Radiology, 2010
- Ultrasound imaging of the carpal tunnel during median nerve compressionCurrent Reviews in Musculoskeletal Medicine, 2009
- Ultrasonographic Reference Values for Assessing the Normal Median Nerve in AdultsJournal of Neuroimaging, 2009
- Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee ModelKorean Journal of Radiology, 2008
- Treatment of carpal tunnel syndrome by low-level laser versus open carpal tunnel releaseLasers in Medical Science, 2007
- Diagnostic Precision of Ultrasonography in Patients with Carpal Tunnel SyndromeAmerican Journal of Physical Medicine & Rehabilitation, 2005
- Diagnostic value of sonography in patients with suspected carpal tunnel syndrome: A prospective studyArthritis & Rheumatism, 2005
- Ultrasonography versus nerve conduction study in patients with carpal tunnel syndrome: substantive or complementary tests?Rheumatology, 2004
- The value of contrast‐enhanced color doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritisArthritis & Rheumatism, 2002
- Carpal tunnel syndrome: diagnosis with high-resolution sonography.American Journal of Roentgenology, 1992