Epicardial Phrenic Nerve Displacement During Catheter Ablation of Atrial and Ventricular Arrhythmias
- 1 August 2015
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (4), 896-904
- https://doi.org/10.1161/circep.115.002818
Abstract
Background— Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. Methods and Results— PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months’ follow up. Conclusions— Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable.Keywords
This publication has 28 references indexed in Scilit:
- Intrapericardial balloon placement for prevention of collateral injury during catheter ablation of the left atrium in a porcine modelHeart Rhythm, 2010
- Prevention of phrenic nerve injury during epicardial ablation: Comparison of methods for separating the phrenic nerve from the epicardial surfaceHeart Rhythm, 2009
- Characterization of the phrenic nerve course within the epicardial substrate of patients with nonischemic cardiomyopathy and ventricular tachycardiaHeart Rhythm, 2009
- Novel Technique to Prevent Left Phrenic Nerve Injury During Epicardial Catheter AblationCirculation, 2008
- A novel method for preventing phrenic nerve injury during catheter ablationHeart Rhythm, 2007
- Phrenic Nerve Injury After Catheter Ablation: Should We Worry About This Complication?Journal of Cardiovascular Electrophysiology, 2006
- Phrenic Nerve Injury After Atrial Fibrillation Catheter Ablation: Characterization and Outcome in a Multicenter StudyJournal of the American College of Cardiology, 2006
- Characterization of Endocardial Electrophysiological Substrate in Patients With Nonischemic Cardiomyopathy and Monomorphic Ventricular TachycardiaCirculation, 2003
- Electrically Unexcitable Scar Mapping Based on Pacing Threshold for Identification of the Reentry Circuit IsthmusCirculation, 2002
- Left phrenic nerve paresis complicating catheter radiofrequency ablation for Wolff-Parkinson-White syndromeAmerican Heart Journal, 1996