Prospective evaluation of a plate haptic toric intraocular lens
- 1 March 2001
- journal article
- research article
- Published by Springer Science and Business Media LLC in Eye
- Vol. 15 (2), 202-205
- https://doi.org/10.1038/eye.2001.61
Abstract
Standard intraocular lenses (IOL) only correct the spherical component of aphakic refractive error. This study describes clinical experience with a foldable, injectable, toric IOL. Keratometric, refractive and visual data were collected on patients listed for cataract surgery. Toric IOLs were offered where keratometric cylinder was greater than 1.5 dioptres. Small-incision phacoemulsification surgery was performed and the IOL implanted with its long axis along the steep corneal axis. Post-operative refractive data were compared with pre-operative and expected refraction using vector analysis software. Results of 22 eyes of 16 consecutive patients implanted with toric IOLs are reported. Two IOLs rotated more than 30 degrees in the first 24 h and were re-dialled surgically. Two further IOLs (9%) rotated more than 30 degrees during follow-up. In 21 of 22 eyes (95%) the refractive astigmatism was reduced, with a mean 73% of planned correction (vector analysis) achieved. The toric IOL is a useful surgical tool to reduce the refractive effects of pre-existing corneal astigmatism. Design modification to prevent IOL rotation would make results more predictable.Keywords
This publication has 10 references indexed in Scilit:
- Postoperative intraocular lens rotation: A randomized comparison of plate and loop haptic implantsOphthalmology, 1999
- Effect of astigmatic keratotomy on spherical equivalent: results of the astigmatism reduction clinical trialAmerican Journal of Ophthalmology, 1999
- Clear Corneal Cataract Surgery and the Correction of Myopia, Hyperopia, and AstigmatismOphthalmology, 1997
- A Prospective Evaluation of Corneal Curvature Changes with 3.0- to 3.5-mm Corneal Tunnel PhacoemulsificationOphthalmology, 1996
- Biofilm-related infections in ophthalmologyEye, 1995
- Astigmatic Excimer Laser Treatment: Theoretical Effects of Axis MisalignmentEuropean journal of Implant and Refractive Surgery, 1994
- Toric intraocular lenses: Correcting astigmatism while controlling axis shiftJournal of Cataract & Refractive Surgery, 1994
- Intraocular Lens Power Calculations for Multifocal Intraocular LensesAmerican Journal of Ophthalmology, 1992
- Development of the SRK/T intraocular lens implant power calculation formulaJournal of Cataract & Refractive Surgery, 1990
- Prescribing cylinders: The problem of distortionSurvey of Ophthalmology, 1977