High-Performance Optical Frequency References for Space
Open Access
- 1 June 2016
- journal article
- research article
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 723 (1), 012047
- https://doi.org/10.1088/1742-6596/723/1/012047
Abstract
A variety of future space missions rely on the availability of high-performance optical clocks with applications in fundamental physics, geoscience, Earth observation and navigation and ranging. Examples are the gravitational wave detector eLISA (evolved Laser Interferometer Space Antenna), the Earth gravity mission NGGM (Next Generation Gravity Mission) and missions, dedicated to tests of Special Relativity, e.g. by performing a Kennedy- Thorndike experiment testing the boost dependence of the speed of light. In this context we developed optical frequency references based on Doppler-free spectroscopy of molecular iodine; compactness and mechanical and thermal stability are main design criteria. With a setup on engineering model (EM) level we demonstrated a frequency stability of about 210-14 at an integration time of 1 s and below 610-15 at integration times between 100s and 1000s, determined from a beat-note measurement with a cavity stabilized laser where a linear drift was removed from the data. A cavity-based frequency reference with focus on improved long-term frequency stability is currently under development. A specific sixfold thermal shield design based on analytical methods and numerical calculations is presented.Keywords
This publication has 13 references indexed in Scilit:
- A space-based optical Kennedy-Thorndike experiment testing special relativityPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2013
- Low-frequency gravitational-wave science with eLISA/NGOClassical and Quantum Gravity, 2012
- Force-insensitive optical cavityOptics Letters, 2011
- Ultrastable assembly and integration technology for ground- and space-based optical systemsApplied Optics, 2010
- Testing local Lorentz and position invariance and variation of fundamental constants by searching the derivative of the comparison frequency between a cryogenic sapphire oscillator and hydrogen maserPhysical Review D, 2010
- Realization of Four-Pass $I_{2}$ Absorption Cell in 532-nm Optical Frequency StandardIEEE Transactions on Instrumentation and Measurement, 2007
- Frequency stabilization of a diode-pumped nd:yag laser at 532 nm to iodine by using third-harmonic techniqueIEEE Transactions on Instrumentation and Measurement, 2003
- Molecular Iodine ClockPhysical Review Letters, 2001
- Portable I/sub 2/-stabilized Nd:YAG laser for international comparisonsIEEE Transactions on Instrumentation and Measurement, 2001
- Laser heterodyne spectroscopy of ^127I_2 hyperfine structure near 532 nmJournal of the Optical Society of America B, 1993