Relationship between sampling duration and concentration of culturable airborne mould and bacteria on selected culture media
Open Access
- 2 November 2006
- journal article
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 102 (6), 1479-1484
- https://doi.org/10.1111/j.1365-2672.2006.03200.x
Abstract
Aims: This study was designed to evaluate potential effects of sampling duration on observed concentrations of airborne culturable mould and bacteria on selected media. Methods and Results: Airborne culturable mould and bacteria from lightly to moderately contaminated environments were collected on selected culture media using two co-located, concurrently operated, Andersen N-6 samplers for five sampling durations in the range of 1–10 min. Differences in mean concentrations, as well as linear relationships between sampling duration and both concentration and variability, were evaluated using nonparametric procedures. For the five sampling durations, there were no significant differences in mean concentrations of mould; for bacteria, there were significant differences, with a trend of decreasing concentrations as sampling duration increased. Data variability decreased with increasing sampling duration for both mould and bacteria. Conclusions: Airborne culturable mould concentrations were similar for sampling durations in the range of 1–10 min. Airborne bacteria concentrations tended to trend downwards with sampling durations exceeding 3 min. Significance and Impact of the Study: This study has shown that sampling durations of 1–10 min are appropriate for collection of airborne culturable mould on malt extract agar (MEA) and dichloran glycerol agar (DG-18); based on the apparent trend of decreasing bacterial sample concentrations associated with increasing sampling duration, sampling durations of ≤3 min may be more appropriate than 5 or 10 min for bacteria on trypticase soy agar (TSA).Keywords
This publication has 18 references indexed in Scilit:
- Invited commentary: is indoor mold exposure a risk factor for asthma?American Journal of Epidemiology, 2003
- Air Sampling Results in Relation to Extent of Fungal Colonization of Building Materials in Some Water-Damaged BuildingsIndoor Air, 2000
- Sensitivity to fungal allergens is a risk factor for life‐threatening asthmaAllergy, 2000
- Acute Pulmonary Hemorrhage in Infants Associated With Exposure to Stachybotrys atra and Other FungiArchives of Pediatrics & Adolescent Medicine, 1998
- Fungal SinusitisThe New England Journal of Medicine, 1997
- Damp housing and adult respiratory symptomsAllergy, 1992
- Quantification of airborne moulds in the homes of children with and without wheeze.Thorax, 1990
- Enumeration and identification of airborne viable mould propagules in housesAllergy, 1990
- Home Dampness and Respiratory Morbidity in ChildrenAmerican Review of Respiratory Disease, 1989
- Positive-Hole Correction of Multiple-Jet Impactors for Collecting Viable MicroorganismsAihaj Journal, 1989