Percutaneous pedicle screw fixation of the lumbar spine
- 1 April 2001
- journal article
- case report
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 10 (4), 1-9
- https://doi.org/10.3171/foc.2001.10.4.11
Abstract
Standard techniques for lumbar pedicle screw fixation involve open exposures and extensive muscle dissection. The purpose of this study was to report the initial clinical experience with a novel device for percutaneous posterior fixation of the lumbar spine. An existing multiaxial lumbar pedicle screw system was modified so that screws could be placed percutaneously by using an extension sleeve that would allow for remote manipulation of the polyaxial screw heads and remote engagement of the screw locking mechanism. A unique rod insertion device was developed that linked to the screw extension sleeves, allowing for a precut, precontoured rod to be placed through a small stab wound. Because the insertion device relies on geometrical constraint of the rod pathway through the screw heads, rods can be placed in a standard submuscular position with minimal manipulation, essentially no muscle dissection, and without the need for direct visual feedback. Twelve patients (six men and six women who ranged in age from 23–68 years) underwent pedicle screw fixation in which the rod insertion device was used. Spondylolisthesis was present in 10 patients and nonunion of a prior interbody fusion was present in two. All patients underwent successful percutaneous fixation. Ten patients underwent single-level fusions (six at L5–S1, three at L4–5, and one at L2–3), and two underwent two-level fusions (one from L–3 to L–5 and the other from L–4 to S–1). The follow-up period ranged from 3 to 12 months (mean 6.8 months). Although percutaneous lumbar pedicle screw placement has been described previously, longitudinal connector (rod or plate) insertion has been more problematic. The device used in this study allows for straightforward placement of lumbar pedicle screws and rods through percutaneous stab wounds. Paraspinous tissue trauma is minimized without compromising the quality of spinal fixation. Preliminary experience with this device has been promising. Standard techniques for lumbar pedicle screw fixation involve open exposures and extensive muscle dissection. The purpose of this study was to report the initial clinical experience with a novel device for percutaneous posterior fixation of the lumbar spine. An existing multiaxial lumbar pedicle screw system was modified so that screws could be placed percutaneously by using an extension sleeve that would allow for remote manipulation of the polyaxial screw heads and remote engagement of the screw locking mechanism. A unique rod insertion device was developed that linked to the screw extension sleeves, allowing for a precut, precontoured rod to be placed through a small stab wound. Because the insertion device relies on geometrical constraint of the rod pathway through the screw heads, rods can be placed in a standard submuscular position with minimal manipulation, essentially no muscle dissection, and without the need for direct visual feedback. Twelve patients (six men and six women who ranged in age from 23–68 years) underwent pedicle screw fixation in which the rod insertion device was used. Spondylolisthesis was present in 10 patients and nonunion of a prior interbody fusion was present in two. All patients underwent successful percutaneous fixation. Ten patients underwent single-level fusions (six at L5–S1, three at L4–5, and one at L2–3), and two underwent two-level fusions (one from L–3 to L–5 and the other from L–4 to S–1). The follow-up period ranged from 3 to 12 months (mean 6.8 months). Although percutaneous lumbar pedicle screw placement has been described previously, longitudinal connector (rod or plate) insertion has been more problematic. The device used in this study allows for straightforward placement of lumbar pedicle screws and rods through percutaneous stab wounds. Paraspinous tissue trauma is minimized without compromising the quality of spinal fixation. Preliminary experience with this device has been promising.Keywords
This publication has 11 references indexed in Scilit:
- Virtual Fluoroscopy: Computer-Assisted Fluoroscopic NavigationSpine, 2001
- Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw InsertionSpine, 2000
- Posterior percutaneous spine instrumentationEuropean Spine Journal, 2000
- Computer-assisted spine surgeryEuropean Spine Journal, 2000
- Virtual fluoroscopyOperative Techniques in Orthopaedics, 2000
- Anatomic Evaluation of Two Different Techniques for the Percutaneous Insertion of Pedicle Screws in the Lumbar SpineSpine, 1999
- Radiation Dose for Pedicle Screw InsertionSpine, 1999
- 1997 Volvo Award Winner in Clinical StudiesSpine, 1997
- A Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal FusionSpine, 1994
- External Skeletal Fixation of the Lower Thoracic and the Lumbar SpinePublished by Springer Science and Business Media LLC ,1982