Risk Factors for Failure of Locked Plate Fixation of Distal Femur Fractures
Top Cited Papers
- 1 February 2014
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Orthopaedic Trauma
- Vol. 28 (2), 83-89
- https://doi.org/10.1097/bot.0b013e31829e6dd0
Abstract
Locked plating has become a standard method to treat supracondylar femur fractures. Emerging evidence indicates that this method of treatment is associated with modest failure rates. The goals of this study were to determine risk factors for complications and to provide technical recommendations for locked plating of supracondylar femur fractures. Retrospective review. Three level I or II trauma centers. Three hundred twenty-six patients with 335 distal femur fractures (OTA 33A or C, 33% open) treated with lateral locked plates were studied. The average patient age was 57 years (range 17-97 years), 55% were women, 34% were obese, 19% were diabetic, and 24% were smokers. All patients were managed with open reduction internal fixation using a lateral distal femoral locked plate construct that included locked screws in the distal fragment and nonlocked, locked, or a combination of locked and nonlocked screws in the proximal fragment. Risk factors for reoperation to promote union, deep infection, and implant failure. After the index procedure, 64 fractures (19%) required reoperation to promote union, including 30 that had a planned staged bone grafting because of the metaphyseal defect after debridement of an open fracture. Independent risk factors for reoperation to promote union and deep infection included diabetes and open fracture. Risk factors for proximal implant failure included open fracture, smoking, increased body mass index, and shorter plate length. The identified risk factors for reoperation to promote union and complications included open fracture, diabetes, smoking, increased body mass index, and shorter plate length. Most factors are out of surgeon control but are useful when considering prognosis. Use of relatively long plates is a technical factor that can reduce risk for fixation failure. Prognostic level II. See instructions for authors for a complete description of levels of evidence.Keywords
This publication has 28 references indexed in Scilit:
- 2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur FracturesClinical Orthopaedics and Related Research, 2011
- Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus FormationJournal of Orthopaedic Trauma, 2010
- Inhibition of fracture healingThe Journal of Bone and Joint Surgery. British volume, 2007
- Femoral Biologic Plate FixationClinical Orthopaedics and Related Research, 2006
- RETROGRADE NAILING VERSUS FIXED‐ANGLE BLADE PLATING FOR SUPRACONDYLAR FEMORAL FRACTURES: A RANDOMIZED CONTROLLED TRIALAnz Journal of Surgery, 2006
- Biomechanical Evaluation of the Less Invasive Stabilization System and the 95-degree Angled Blade Plate for the Internal Fixation of Distal Femur Fractures in Human Cadaveric Bones with High Bone Mineral DensityThe Journal of Trauma and Acute Care Surgery, 2006
- Treatment of Distal Femur Fractures Using the Less Invasive Stabilization SystemJournal of Orthopaedic Trauma, 2004
- The Influence of Diabetes Mellitus on the Healing of Closed FracturesClinical Orthopaedics and Related Research, 1988
- Problems in the Management of Type III (Severe) Open FracturesThe Journal of Trauma and Acute Care Surgery, 1984
- Two-Plane Fixation of Acute Supracondylar and Intracondylar Fractures of the FemurSouthern Medical Journal, 1978