Abstract
Purpose: TheGEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states ( H 0 , H + ) and ( He 0 , He + , He 2 + ), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called “GEANT4-DNA” physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in theGEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov–Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data withGEANT4microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: TheGEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.Keywords
This publication has 65 references indexed in Scilit:
- Molecular scale track structure simulations in liquid water using the Geant4-DNA Monte-Carlo processesApplied Radiation and Isotopes, 2011
- Geometry and physics of the Geant4 toolkit for high and medium energy applicationsRadiation Physics and Chemistry, 2009
- Monte Carlo dosimetry for targeted irradiation of individual cells using a microbeam facilityRadiation Protection Dosimetry, 2009
- A detailed ray-tracing simulation of the high resolution microbeam at the AIFIRA facilityNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2008
- Geant4 Physics Processes for Microdosimetry Simulation: Design Foundation and Implementation of the First Set of ModelsIEEE Transactions on Nuclear Science, 2007
- Energy distribution mapping of beta radioactive sourcesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Accurate Electron Inelastic Cross Sections and Stopping Powers for Liquid Water over the 0.1-10 keV Range Based on an Improved Dielectric Description of the Bethe SurfaceRadiation Research, 2007
- Monte Carlo Simulation of Electromagnetic Interactions of Radiation with Liquid Water in the Framework of the Geant4-DNA ProjectPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- Monte Carlo simulation of the energy loss of low-energy electrons in liquid waterPhysics in Medicine & Biology, 2003
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003