A particle track-repeating algorithm for proton beam dose calculation
- 18 February 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (5), 1001-1010
- https://doi.org/10.1088/0031-9155/50/5/022
Abstract
A particle track-repeating algorithm has been developed for proton beam dose calculation for radiotherapy. Monoenergetic protons with 250 MeV kinetic energy were simulated in an infinite water phantom using the GEANT3 Monte Carlo code. The changes in location, angle and energy for every transport step and the energy deposition along the track were recorded for the primary protons and all secondary particles. When calculating dose for a patient with a realistic proton beam, the pre-generated particle tracks were repeated in the patient geometry consisting of air, soft tissue and bone. The medium and density for each dose scoring voxel in the patient geometry were derived from patient CT data. The starting point, at which a proton track was repeated, was determined according to the incident proton energy. Thus, any protons with kinetic energy less than 250 MeV can be simulated. Based on the direction of the incident proton, the tracks were first rotated and for the subsequent steps, the scattering angles were simply repeated for air and soft tissue but adjusted properly based on the scattering power for bone. The particle step lengths were adjusted based on the density for air and soft tissue and also on the stopping powers for bone while keeping the energy deposition unchanged in each step. The difference in nuclear interactions and secondary particle generation between water and these materials was ignored. The algorithm has been validated by comparing the dose distributions in uniform water and layered heterogeneous phantoms with those calculated using the GEANT3 code for 120, 150, 180 and 250 MeV proton beams. The differences between them were within 2%. The new algorithm was about 13 times faster than the GEANT3 Monte Carlo code for a uniform phantom geometry and over 700 times faster for a heterogeneous phantom geometry.This publication has 24 references indexed in Scilit:
- A Monte Carlo dose calculation algorithm for proton therapyMedical Physics, 2004
- Intensity modulated radiation therapy using laser-accelerated protons: a Monte Carlo dosimetric studyPhysics in Medicine & Biology, 2003
- Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculationsPhysics in Medicine & Biology, 2003
- Particle in cell simulation of laser‐accelerated proton beams for radiation therapyMedical Physics, 2002
- A Monte Carlo dose calculation tool for radiotherapy treatment planningPhysics in Medicine & Biology, 2002
- Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planningPhysics in Medicine & Biology, 2000
- Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMCPhysics in Medicine & Biology, 2000
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- A pencil beam algorithm for proton dose calculationsPhysics in Medicine & Biology, 1996
- Superposition dose calculation incorporating Monte Carlo generated electron track kernelsMedical Physics, 1996