Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens system
- 1 February 2007
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Cataract & Refractive Surgery
- Vol. 33 (2), 197-202
- https://doi.org/10.1016/j.jcrs.2006.09.033
Abstract
PURPOSE: To assess the quality of vision in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions. SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS: The study comprised 343 consecutive patients who had bilateral implantation of the Acri.Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were determined. RESULTS: Eyes with the 737D IOL had better best corrected distance acuity than eyes with the 733D IOL (mean 0.036 ± 0.061 logMAR versus 0.141 ± 0.131 logMAR) (P<.0001). Eyes with the 733D IOL had better best distance corrected near acuity than eyes with the 737D IOL (mean 0.015 ± 0.115 logMAR versus 0.059 ± 0.091 logMAR) (P = .0027). Binocularly, the Acri.Twin system allowed good distance and near vision; the means were 0.031 ± 0.059 logMAR and 0.005 ± 0.024 logMAR, respectively. Contrast sensitivity with the Acri.Twin system was within normal limits under photopic and mesopic conditions. Contrast sensitivity was statistically significantly better with the Acri.Twin system, followed by the 737D IOL and the 733D IOL under both illumination levels. CONCLUSIONS: Asymmetric bilateral implantation of the Acri.Twin IOL gave good simultaneous distance and near vision with improved contrast sensitivity under photopic and mesopic conditions. Differences between monocular and binocular visual acuity and contrast sensitivity were obtained because of the distance-/near-weighted light distribution of Acri.Twin IOLs.Keywords
This publication has 14 references indexed in Scilit:
- Secondary diffractive bifocal piggyback intraocular lens implantationJournal of Cataract & Refractive Surgery, 2006
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006
- Contrast sensitivity function in eyes with diffractive bifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2005
- Visual performance with multifocal intraocular lensesOphthalmology, 2004
- Multifocal versus monofocal intraocular lenses in cataract surgeryOphthalmology, 2003
- Cataract extraction with multifocal intraocular lens implantation: A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomesOphthalmology, 2000
- A prospective comparative study of the amo array zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lensOphthalmology, 1999
- Theoretische und klinische Abbildungseigenschaften refraktiver 3-Zonen-Multifokallinsen mit unterschiedlicher Gewichtung von Fern- und NahfokusKlinische Monatsblätter für Augenheilkunde, 1994
- Spatial Modulation Transfer in the Human EyeJournal of the Optical Society of America, 1967
- Monocular versus Binocular Visual AcuityNature, 1965