Fetal head–symphysis distance: a simple and reliable ultrasound index of fetal head station in labor
- 6 March 2013
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 41 (4), 419-424
- https://doi.org/10.1002/uog.12335
Abstract
Objectives To assess the reproducibility of measurement of a new sonographic index of fetal head station in labor, the fetal head–symphysis distance (HSD), using three‐dimensional ultrasound, and its correlation with digital assessment of fetal head descent and with the angle of progression (AoP). Methods Three‐dimensional (3D) ultrasound volumes were acquired from 47 nulliparous women in active labor following assessment of fetal head station with digital examination. The HSD (the distance between the lower edge of the pubic symphysis and the nearest point of the fetal skull) was measured independently by two operators in order to evaluate intra‐ and interobserver reproducibility. The correlation between HSD, AoP and fetal head station was evaluated using regression analysis. Using 3D tomographic ultrasound imaging (TUI), measurements of the HSD were obtained in different parasagittal planes to evaluate the influence of inaccurate alignment of the probe with the midline of the pelvis. Results Measurement of HSD showed high intraobserver (intraclass correlation coefficient (ICC) = 0.995; 95% CI, 0.991–0.997) and interobserver (ICC = 0.991; 95% CI, 0.984–0.995) reliability. In addition, a high correlation was demonstrated between mid‐sagittal and parasagittal HSD measurements. HSD showed significant negative correlation with both fetal head station and AoP. Conclusion Fetal HSD is a simple and reliable method for the assessment of fetal head descent in labor. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.Keywords
This publication has 23 references indexed in Scilit:
- Ultrasound in labor: a caregiver's perspectiveUltrasound in Obstetrics & Gynecology, 2013
- Can sonographic depiction of fetal head position prior to or at the onset of labor predict mode of delivery?Ultrasound in Obstetrics & Gynecology, 2012
- Three‐dimensional ultrasound in monitoring progression of labor: a reproducibility studyUltrasound in Obstetrics & Gynecology, 2010
- What is the most reliable ultrasound parameter for assessment of fetal head descent?Ultrasound in Obstetrics & Gynecology, 2010
- A question of angle of viewUltrasound in Obstetrics & Gynecology, 2009
- Prediction of labor and delivery by transperineal ultrasound in pregnancies with prelabor rupture of membranes at termUltrasound in Obstetrics & Gynecology, 2006
- Birth simulator: Reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classificationAmerican Journal of Obstetrics and Gynecology, 2005
- Applying the right statistics: analyses of measurement studiesUltrasound in Obstetrics & Gynecology, 2003
- Intrapartum fetal head position II: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the second stage of laborUltrasound in Obstetrics & Gynecology, 2002
- Intrapartum sonography to determine fetal head positionThe Journal of Maternal-Fetal & Neonatal Medicine, 2002