Drag constants for common indoor bioaerosols
- 30 December 2013
- journal article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 24 (3), 401-413
- https://doi.org/10.1177/1420326x13515897
Abstract
In practice, the drag coefficient of a particle is usually calculated using empirical relationships obtained by generalizing experimental data. This study demonstrates that using the default Stokes’ law settings in FLUENT to computationally predict the drag coefficients for bioaerosol deposition is not really appropriate: the average fractional bias is 7% and the average normalized mean square error is 15%. Comparatively, the errors for bacteria (−12% to 24%) are larger than those for fungi (−8% to 26%). These errors, however, can be minimized by selecting a suitable drag constant, which can be determined based on the bioaerosol diameter. The average drag constants for bacteria were shown by the results to vary from 0.25 to 3.1, which are much smaller than the default value of 24, whereas the values for fungi were generally larger and in a wider range. This study also investigated the correlation between the drag coefficient and Reynolds number for common indoor bioaerosols with diameters between 0.69 and 8.6 µm. The outcome of this study would therefore provide a good reference point for future estimation of the deposition distribution patterns of various common indoor bioaerosols.Keywords
This publication has 25 references indexed in Scilit:
- Evolution of Ultrafine Particle Size Distributions Following Indoor Episodic Releases: Relative Importance of Coagulation, Deposition and VentilationAerosol Science and Technology, 2012
- Automated Spore Measurements Using Microscopy, Image Analysis, and Peak Recognition of Near-Monodisperse AerosolsAerosol Science and Technology, 2012
- Determination of particle deposition in enclosed spaces by Detached Eddy Simulation with the Lagrangian methodAtmospheric Environment, 2011
- Effect of particle spatial distribution on particle deposition in ventilation roomsJournal of Hazardous Materials, 2009
- Indoor and outdoor airborne bacteria in child day-care centers in Edirne City (Turkey), seasonal distribution and influence of meteorological factorsEnvironmental Monitoring and Assessment, 2009
- Deposition rates on smooth surfaces and coagulation of aerosol particles inside a test chamberAtmospheric Environment, 2009
- An evidential example of airborne bacteria in a crowded, underground public concourse in TokyoAtmospheric Environment, 2005
- Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildingsIndoor Air, 2005
- Verification of Codes and CalculationsAIAA Journal, 1998
- Modeling and measurement of the effective drag coefficient in decelerating and non-accelerating turbulent gas—solids dilute phase flow of large partiPowder Technology, 1993