Airflow and Cooling in a Data Center
Open Access
- 27 April 2010
- journal article
- Published by ASME International in Journal of Heat Transfer
- Vol. 132 (7), 073001
- https://doi.org/10.1115/1.4000703
Abstract
This paper deals with the distribution of airflow and the resulting cooling in a data center. First, the cooling challenge is described and the concept of a raised-floor data center is introduced. In this arrangement, cooling air is supplied through perforated tiles. The flow rates of the cooling air must meet the cooling requirements of the computer servers placed next to the tiles. These airflow rates are governed primarily by the pressure distribution under the raised floor. Thus, the key to modifying the flow rates is to influence the flow field in the under-floor plenum. Computational fluid dynamics (CFD) is used to provide insight into various factors affecting the airflow distribution and the corresponding cooling. A number of ways of controlling the airflow distribution are explored. Then attention is turned to the above-floor space, where the focus is on preventing the hot air from entering the inlets of computer serves. Different strategies for doing this are considered. The paper includes a number of comparisons of measurements with the results of CFD simulations.Keywords
This publication has 15 references indexed in Scilit:
- Distributed Leakage Flow in Raised-Floor Data CentersPublished by ASME International ,2005
- Cluster of High-Powered Racks Within a Raised-Floor Computer Data Center: Effect of Perforated Tile Flow Distribution on Rack Inlet Air TemperaturesJournal of Electronic Packaging, 2004
- Thermal considerations in cooling large scale high compute density data centersPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Raised floor computer data center: effect on rack inlet temperatures of chilled air exiting both the hot and cold aislesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Use of Computational Fluid Dynamics for Calculating Flow Rates Through Perforated Tiles in Raised-Floor Data CentersHVAC&R Research, 2003
- Efficient Thermal Management of Data Centers—Immediate and Long-Term Research NeedsHVAC&R Research, 2003
- Techniques for Controlling Airflow Distribution in Raised-Floor Data CentersPublished by ASME International ,2003
- A Hybrid Methodology for the Optimization of Data Center Room LayoutPublished by ASME International ,2003
- An innovative approach to the environmental system design for TLC rooms in Telecom ItaliaPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- A methodology for the design of perforated tiles in raised floor data centers using computational flow analysisIEEE Transactions on Components and Packaging Technologies, 2001