Purpose Penile prosthetic surgery is associated with satisfaction rates >90% for the general penile implant population. It is suggested that satisfaction rates may be lower in certain populations. This study was undertaken to define potential predictors of satisfaction. Methods Patients undergoing penile prosthesis surgery completed the International Index of Erectile Function (IIEF) prior to surgery, and the IIEF and Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) questionnaires at least 6 months postoperatively accompanied by a Global Satisfaction Question (GSQ). Results A total of 114 patients constituted the study population. Subgroups evaluated included patients with Peyronie’s disease (PD), body mass index (BMI) > 30 kg/m2, radical prostatectomy (RP), and patient age > 70 years. The mean patient age and duration of ED were 59 ± 14 and 3.2 ± 1.9 years, respectively. All groups demonstrated statistically significant differences between pre‐ and postoperative scores for the IIEF and EDITS. Patients with PD, a history of RP, and BMI > 30 kg/m2 had significantly lower scores on the GSQ, IIEF satisfaction domain, and EDITS compared with the general implant population. Only PD impacted negatively on the postoperative IIEF erectile function domain score. On the multivariate analysis, factors associated with ≥5‐point difference in the IIEF satisfaction domain score compared with the general implant population were PD (RR = 4.2), RP (RR = 2.2), and BMI > 30 (RR = 1.8). Conclusions These data suggest that men diagnosed with PD, BMI > 30, or previous RP undergoing penile prosthesis surgery have lower satisfaction rates than the general penile implant population. Akin‐Olugbade O, Parker M, Guhring P, and Mulhall J. Determinants of patient satisfaction following penile prosthesis surgery. J Sex Med 2006;3:743–748.This publication has 16 references indexed in Scilit:
- Serial Assessment Of Efficacy And Satisfaction Profiles Following Penile Prosthesis SurgeryJournal of Urology, 2003
- MECHANICAL RELIABILITY AND SAFETY OF, AND PATIENT SATISFACTION WITH THE AMBICOR INFLATABLE PENILE PROSTHESIS: RESULTS OF A 2 CENTER STUDYJournal of Urology, 2001
- AMS Three–Piece Inflatable Implants for Erectile Dysfunction: A Long–Term Multi–Institutional Study in 200 Consecutive PatientsEuropean Urology, 2000
- Assessment of psychosexual adjustment after insertion of inflatable penile prosthesisUrology, 1998
- Mechanical reliability, surgical complications, and patient and partner satisfaction of the modern three-piece inflatable penile prosthesisUrology, 1998
- Long-term mechanical reliability of multicomponent inflatable penile prosthesis: comparison of device survivalUrology, 1998
- Penile prosthesis implantation in the treatment of Peyronie’s diseaseInternational Journal of Impotence Research, 1998
- The international index of erectile function (IIEF): a multidimensional scale for assessment of erectile dysfunctionUrology, 1997
- Safety and Efficacy Outcome of Mentor Alpha-1 Inflatable Penile Prosthesis Implantation for Impotence TreatmentJournal of Urology, 1997
- Early Experience with the First Pre-connected 3-Piece Inflatable Penile Prosthesis: The Mentor Alpha-1Journal of Urology, 1993