A Multisite Assessment of the Quantitative Capabilities of the Xpert MTB/RIF Assay
- 1 November 2011
- journal article
- research article
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 184 (9), 1076-1084
- https://doi.org/10.1164/rccm.201103-0536oc
Abstract
The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterial burden is an important biomarker for disease severity, infection control risk, and response to therapy. Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. Xpert MTB/RIF results were compared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r(s) = -0.77) and directly from sputum (r(s) =-0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r(s) = 0.68) and semiquantitative colony counts (r(s) = -0.56) was weaker than smear. Tests of paired same-patient sputum showed that high viscosity sputum samples contained ×32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier in microscopy. Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.Keywords
This publication has 30 references indexed in Scilit:
- Suitability of Xpert MTB/RIF and Genotype MTBDR plus for Patient Selection for a Tuberculosis Clinical TrialJournal of Clinical Microbiology, 2011
- Evaluation of the Xpert MTB/RIF Assay for the Diagnosis of Pulmonary Tuberculosis in a High HIV Prevalence SettingAmerican Journal of Respiratory and Critical Care Medicine, 2011
- Comparison of the Xpert MTB/RIF Test with an IS 6110 -TaqMan Real-Time PCR Assay for Direct Detection of Mycobacterium tuberculosis in Respiratory and Nonrespiratory SpecimensJournal of Clinical Microbiology, 2011
- Evaluation of the Cepheid Xpert MTB/RIF Assay for Direct Detection of Mycobacterium tuberculosis Complex in Respiratory SpecimensJournal of Clinical Microbiology, 2011
- Rapid Molecular Detection of Extrapulmonary Tuberculosis by the Automated GeneXpert MTB/RIF SystemJournal of Clinical Microbiology, 2011
- Rapid Detection of Mycobacterium tuberculosis Complex and Rifampin Resistance in Smear-Negative Clinical Samples by Use of an Integrated Real-Time PCR MethodJournal of Clinical Microbiology, 2011
- Rapid Molecular Detection of Tuberculosis and Rifampin ResistanceThe New England Journal of Medicine, 2010
- Rapid Detection of Mycobacterium tuberculosis and Rifampin Resistance by Use of On-Demand, Near-Patient TechnologyJournal of Clinical Microbiology, 2010
- Insufficient quality of sputum submitted for tuberculosis diagnosis and associated factors, in Klaten district, IndonesiaBMC Pulmonary Medicine, 2009
- Cavitary Disease and Quantitative Sputum Bacillary Load in Cases of Pulmonary TuberculosisJournal of Clinical Microbiology, 2007