Abnormal left ventricular intracavitary flow acceleration in patients undergoing aortic valve replacement for aortic stenosis. A marker for high postoperative morbidity and mortality.
- 1 September 1992
- journal article
- abstracts
- Published by Ovid Technologies (Wolters Kluwer Health) in Circulation
- Vol. 86 (3), 926-936
- https://doi.org/10.1161/01.cir.86.3.926
Abstract
BACKGROUND We examined the clinical and echocardiographic characteristics of patients undergoing aortic valve replacement for aortic stenosis whose continuous wave Doppler studies showed abnormal intracavitary flow acceleration. METHODS AND RESULTS The clinical and Doppler echocardiographic records of 53 consecutive patients undergoing aortic valve replacement for aortic stenosis were reviewed. Doppler echocardiography was performed at a mean of 6.6 days (range, 0-22 days) after surgery. Thirteen patients (group 1) had a dagger-shaped high-velocity systolic flow signal indicative of abnormal intracavitary flow acceleration on their postoperative Doppler study; group 2 comprised 40 aortic stenosis patients who underwent aortic valve replacement but had no postoperative evidence of abnormal intracavitary flow acceleration. Group 1 postoperative abnormal intracavitary flow velocities ranged from 1.8 to 6.8 m/sec (mean, 4.9 +/- 0.9 m/sec): Resulting dynamic gradients ranged from 10 to 184 mm Hg (mean, 104.6 +/- 32 mm Hg). Compared with group 2, group 1 patients had a distinctive ventricular geometry with more-pronounced hypertrophy, smaller cavities, and higher ejection fraction. Systolic anterior motion of the mitral valve did not accompany abnormal intracavitary flow acceleration in any patient. Six of 13 group 1 patients suffered postoperative hemodynamic compromise characterized by severe hypotension despite adequate pulmonary capillary wedge pressures; group 1 postoperative mortality was significantly greater than that seen in group 2 patients (38% versus 12%, p less than 0.05). CONCLUSIONS Abnormal intracavitary flow acceleration after aortic valve replacement for severe aortic stenosis is associated with a distinctive ventricular geometry and supernormal systolic function but not systolic anterior motion of the mitral valve. Such flow acceleration appears to be a marker for increased postoperative morbidity and mortality. Preoperative and postoperative Doppler echocardiography may be useful in risk stratification and guiding therapy.Keywords
This publication has 26 references indexed in Scilit:
- Midventricular obstruction associated with chronic systemic hypertension and severe left ventricular hypertrophyThe American Journal of Cardiology, 1991
- Diversity of patterns of hypertrophy in patients with systemic hypertension and marked left ventricular wall thickeningThe American Journal of Cardiology, 1990
- Hypertensive Hypertrophic Cardiomyopathy of the ElderlyNew England Journal of Medicine, 1985
- Hypertrophic cardiomyopathy: Recent observations regarding the specificity of three hallmarks of the disease: Asymmetric septal hypertrophy, septal disorganization and systolic anterior motion of the anterior mitral leafletThe American Journal of Cardiology, 1980
- Hypertrophic cardiomyopathy after aortic valve replacementThe American Journal of Cardiology, 1980
- The association of fixed and dynamic left ventricular outflow obstructionAmerican Heart Journal, 1975
- Echocardiography in Coexisting Hypertrophic Subaortic Stenosis and Fixed Left Ventricular Outflow ObstructionCirculation, 1974
- Coexistent fixed congenital and idiopathic hypertrophic subaortic stenosisThe American Journal of Cardiology, 1973
- Coexistent aortic valvular and functional hypertrophic subaortic stenosis: Clinical, physiologic and angiographic aspectsThe American Journal of Cardiology, 1969
- The use of single plane angiocardiograms for the calculation of left ventricular volume in manAmerican Heart Journal, 1968