Monitoring Granulation Rate Processes Using Three PAT Tools in a Pilot-Scale Fluidized Bed
- 11 October 2008
- journal article
- Published by Springer Science and Business Media LLC in AAPS PharmSciTech
- Vol. 9 (4), 1083-1091
- https://doi.org/10.1208/s12249-008-9145-6
Abstract
The purpose of this research was to analyze and compare the responses of three Process Analytical Technology (PAT) techniques applied simultaneously to monitor a pilot-scale fluidized bed granulation process. Real-time measurements using focused beam reflectance measurement (Lasentec FBRM) and near-infra red spectroscopy (Bruker NIR) were taken by inserting in-line probes into the fluidized bed. Non-intrusive acoustic emission measurements (Physical Acoustic AE) were performed by attaching piezoelectric sensors on the external wall of the fluidized bed. Powder samples were collected at regular intervals during the granulation process and characterized offline using laser diffraction, scanning electron microscopy, stereo-optical microscopy and loss on drying method. PAT data comprising chord length distribution and chord count (from FBRM), absorption spectra (from NIR) and average signal levels and counts (from AE) were compared with the particle properties measured using offline samples. All three PAT techniques were able to detect the three granulation regimes or rate processes (wetting and nucleation, consolidation and growth, breakage) to varying degrees of sensitivity. Being dependent on optical signals, the sensitivities of the FBRM and NIR techniques were susceptible to fouling on probe windows. The AE technique was sensitive to background fluidizing air flows and external interferences. The sensitivity, strengths and weaknesses of the PAT techniques examined may facilitate the selection of suitable PAT tools for process development and scale-up studies.Keywords
This publication has 26 references indexed in Scilit:
- Acoustic monitoring of a fluidized bed coating processInternational Journal of Pharmaceutics, 2007
- Obtaining Particle Size Distribution from Chord Length MeasurementsParticle & Particle Systems Characterization, 2006
- Restoration of PSD from Chord Length Distribution Data using the Method of Projections onto Convex SetsParticle & Particle Systems Characterization, 2005
- Near-infrared spectroscopy and imaging: Basic principles and pharmaceutical applicationsAdvanced Drug Delivery Reviews, 2005
- Process Analytical Technology: An Investment in Process KnowledgeOrganic Process Research & Development, 2005
- Scaling up of the fluidized bed granulation processInternational Journal of Pharmaceutics, 2003
- Choice of the Focal Point Position Using Lasentec FBRMParticle & Particle Systems Characterization, 2003
- In-line moisture measurement during granulation with a four-wavelength near infrared sensor: an evaluation of particle size and binder effectsEuropean Journal of Pharmaceutics and Biopharmaceutics, 2000
- Process control and end-point determination of a fluid bed granulation by application of near infra-red spectroscopyInternational Journal of Pharmaceutics, 1997
- Types of gas fluidizationPowder Technology, 1973