A paper electrode integrated lateral flow immunosensor for quantitative analysis of oxidative stress induced DNA damage
- 12 March 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (11), 2850-2857
- https://doi.org/10.1039/c4an00313f
Abstract
A novel device combining electrochemical and colorimetric detection is developed for the rapid measurement of 8-hydroxy-2′-deoxyguanosine (8-OHdG), a DNA oxidative damage biomarker. The device takes advantage of the speed and low cost of the conventional strip test as well as the high reliability and accuracy of the electrochemical assay. Competitive immunoreactions were performed on the lateral flow strip, and the captured 8-OHdG on the control line was determined by chronoamperometric measurement with carbon nanotube paper as the working electrode. At the same time, the color intensity of the test line was measured by a scanner and analyzed by the ImageJ software. The device was able to detect 8-OHdG concentrations in PBS as low as 2.07 ng mL−1 by the colorimetric method and 3.11 ng mL−1 by the electrochemical method. Furthermore, the device was successfully utilized to detect 8-OHdG in urine with a detection limit of 5.76 ng mL−1 (colorimetric method) and 8.85 ng mL−1 (electrochemical method), respectively. In conclusion, the integrated device with dual detection methods can provide a rapid, visual, quantitative and feasible detection method for 8-OHdG. The integration of these two methods holds two major advantages over tests based on a single method. Firstly, it can provide double confidence on the same assay. Secondly, by involving two methods that differ in principle, the integration could potentially avoid false results coming from one method. In addition, these methods do not require expensive equipment or trained personnel, making it suitable for use as a simple, economical, portable field kit for on-site monitoring of 8-OHdG in a variety of clinical settings.Keywords
This publication has 30 references indexed in Scilit:
- Paper based point-of-care testing disc for multiplex whole cell bacteria analysisBiosensors and Bioelectronics, 2011
- Assessment of oxidative DNA damage and repair at single cellular level via real-time monitoring of 8-OHdG biomarkerBiosensors and Bioelectronics, 2010
- Use of multiple colorimetric indicators for paper-based microfluidic devicesAnalytica Chimica Acta, 2010
- Aptamer−Nanoparticle Strip Biosensor for Sensitive Detection of Cancer CellsAnalytical Chemistry, 2009
- Quantitative Immunochromatographic Strip Biosensor for the Detection of Carcinoembryonic Antigen Tumor Biomarker in Human PlasmaAmerican Journal of Biomedical Sciences, 2009
- Determination of 8-hydroxy-2'deoxyguanosine in Urine Using HPLC With Electrochemical DetectionArchives of Industrial Hygiene and Toxicology, 2008
- Evaluation of enzyme-linked immunosorbent assay and liquid chromatography–tandem mass spectrometry methodology for the analysis of 8-oxo-7,8-dihydro-2′-deoxyguanosine in saliva and urineFree Radical Biology & Medicine, 2006
- Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion labelThe Analyst, 2005
- Electrochemical and enzymic oxidation of guanosine and 8-hydroxyguanosine and the effects of oxidation products in miceBioelectrochemistry and Bioenergetics, 1997
- p53 Mutations in Human CancersScience, 1991