Analytical modelling of Kirschner wires in Ilizarov circular external fixator as pretensioned slender beams
- 22 July 2008
- journal article
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (32), 243-256
- https://doi.org/10.1098/rsif.2008.0251
Abstract
Transfixing thin Kirschner wires (K-wires) are the key components of the Ilizarov fixator regarding its axial stiffness, which affects the mechanobiological environment in which bone is healed. Mechanically speaking, K-wires are slender beams that are axially tensioned, then fixed and transversely loaded. The existing solutions to such a problem either do not accommodate any axial loading prior to transverse loading, or do not account for the change in the axial load (reaction) due to transverse loading. Their applicability is also limited vis-à-vis applied loads and beam dimensions. This work seeks to address those problems by providing a mathematical formulation for a pretensioned slender beam that accounts for the change in the beam tension due to lateral loading. Central loading of a pretensioned beam was studied and new polynomial equations have been derived, the roots of which yield the final tension for a (i) long, slender and heavily loaded beam and (ii) relatively thicker beam subjected to a lower load. Results were produced and discussed for the specific application of pretensioned K-wires in circular (ring) external fixators in orthopaedics (such as Ilizarov's), which were checked (validated) via two- and three-dimensional finite-element analyses.Keywords
This publication has 28 references indexed in Scilit:
- Analytical modelling of Kirschner wires in Ilizarov circular external fixators using a tensile modelProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2008
- Why fine-wire fixators work: An analysis of pressure distribution at the wire–bone interfaceJournal of Biomechanics, 2007
- Finite element modelling of the Ilizarov external fixation systemProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2007
- The Ilizarov external fixator: What remains of the wire pretension after dynamic loading?Clinical Biomechanics, 2005
- Wire Tension in the Ilizarov System: Accuracy of the Wire-Tensioning DeviceProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2005
- Quantitative assessment of tension in wires of fine-wire external fixatorsMedical Engineering & Physics, 2005
- Avoiding the material nonlinearity in an external fixation deviceClinical Biomechanics, 2004
- Geometric and material nonlinearity in tensioned wires of an external fixatorClinical Biomechanics, 2004
- Mechanical Forces as Predictors of Healing During Tibia1 Lengthening by Distraction OsteogenesisClinical Orthopaedics and Related Research, 1994
- A Biomechanical Analysis of the Ilizarov External FixatorClinical Orthopaedics and Related Research, 1989