Training and Magnetic Field Measurements of the ANKA Superconducting Undulator
- 9 November 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3), 1760-1763
- https://doi.org/10.1109/tasc.2010.2085070
Abstract
In this contribution we report the results of the training and of the local field measurements performed in a liquid helium bath of the ANKA superconducting undulator. The period length is 15 mm and the coils are 1.5 m long. The key specifications of the system are an undulator parameter K higher than 2 (for a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. The superconducting undulator is planned to be installed in the ANKA storage ring by the beginning of 2011 to be the light source of the new beamline NANO for high resolution X-ray diffraction..Keywords
This publication has 4 references indexed in Scilit:
- Generation of x-ray radiation in a storage ring by a superconductive cold-bore in-vacuum undulatorPhysical Review Special Topics - Accelerators and Beams, 2006
- Magnetic calculations of a superconducting undulator at the ESRFNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Cryogenic permanent magnet undulatorsPhysical Review Special Topics - Accelerators and Beams, 2004
- A three-dimensional magnetostatics computer code for insertion devicesJournal of Synchrotron Radiation, 1998