Computed Tomography Evaluation of Pedicle Screws Placed in the Pediatric Deformed Spine Over an 8-Year Period
- 1 November 2007
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Spine
- Vol. 32 (24), 2679-2684
- https://doi.org/10.1097/brs.0b013e31815a7f13
Abstract
A retrospective review. To evaluate the incremental accuracy of pedicle screws used in spinal deformity via a free-hand technique at a single institution over an 8-year period. The in vivo accuracy of free-hand pedicle screws placed throughout the deformed spine as evaluated by computed tomography (CT) scanning is unknown over a long time period. A total of 1023 pedicle screws inserted from T1 to L4 in 60 patients (928 screws in 54 scoliosis patients and 95 screws in 6 kyphosis patients) over an 8-year period were investigated via postoperative CT scans. Patients were divided into 3 groups (group I = 1998-1999, group II = 2001-2002, and group III = 2005). All pedicle screws were inserted via the free-hand technique using anatomic landmarks, specific entry sites, neurophysiologic, and radiographic confirmation. Pedicle screw position on CT scan was graded as acceptable versus violated, defined as the screw axis being outside the pedicle wall. One hundred seven of 1023 pedicle screws (10.5%) demonstrated significant mediolateral pedicle wall violations (19 medial vs. 88 lateral, P = 0.001). groups I and III had significantly higher lateral wall violations than group II (P < 0.05) as did the kyphotic spines (vs. scoliotic spine, P < 0.05). There were significantly more screws placed in the periapical region over time (P < 0.0001), with left-sided lateral violations (T5-T8) increasing from group II to group III, while the number of medial violations significantly decreased with time (P < 0.0001). Pedicle screws placed on the right side showed a significant decrease in accuracy from group II to group III (P = 0.03). The average transverse angle of the acceptable screws was 15.3 degrees which was significantly different from the medial (23.0 degrees , P < 0.001) and lateral (10.6 degrees , P < 0.001) violations between group I and group II. No screws demonstrated neurologic, vascular, or visceral complications. Overall accuracy of acceptable screws using the free-hand pedicle screw placement technique in the deformed spine was 89.5%, without any neurologic, vascular, or visceral complications over an 8-year period. The rate of medial violations decreased with time, as the number of screws placed in the periapical region increased.Keywords
This publication has 32 references indexed in Scilit:
- Accuracy and Efficacy of Thoracic Pedicle Screws in Curves More Than 90°Spine, 2005
- In Vivo Accuracy of Thoracic Pedicle ScrewsSpine, 2001
- The Use of Pedicle-Screw Internal Fixation for the Operative Treatment of Spinal Disorders*The Journal of Bone and Joint Surgery-American Volume, 2000
- Complications Associated with Pedicle Screws*The Journal of Bone & Joint Surgery, 1999
- Anatomic Relations of the Thoracic Pedicle to the Adjacent Neural StructuresSpine, 1997
- The Use of Pedicle Screw Fixation to Improve Correction in the Lumbar Spine of Patients With Idiopathic ScoliosisSpine, 1996
- Placement of pedicle screws in the thoracic spine. Part IIThe Journal of Bone & Joint Surgery, 1995
- Placement of pedicle screws in the thoracic spine. Part IThe Journal of Bone & Joint Surgery, 1995
- Segmental Pedicle Screw Fixation in the Treatment of Thoracic Idiopathic ScoliosisSpine, 1995