Background—: Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. Methods and Results—: Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections ( r =0.682, P P =0.01). Conclusions—: Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.Keywords
This publication has 13 references indexed in Scilit:
- Multidetector Computed Tomography in Transcatheter Aortic Valve ImplantationJACC: Cardiovascular Imaging, 2011
- Multislice Computed Tomography for Prediction of Optimal Angiographic Deployment Projections During Transcatheter Aortic Valve ImplantationJACC: Cardiovascular Interventions, 2010
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Image‐Integration of Intraprocedural Rotational Angiography‐Based 3D Reconstructions of Left Atrium and Pulmonary Veins into Electroanatomical Mapping: Accuracy of a Novel Modality in Atrial Fibrillation AblationJournal of Cardiovascular Electrophysiology, 2010
- Effective dose analysis of three-dimensional rotational angiography during catheter ablation proceduresPhysics in Medicine & Biology, 2010
- Dyna-CT During Minimally Invasive Off-Pump Transapical Aortic Valve ImplantationThe Annals of Thoracic Surgery, 2009
- Transcatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related OutcomesCirculation, 2009
- DynaCT during EVAR – A Comparison with Multidetector CTEuropean Journal of Vascular and Endovascular Surgery, 2009
- Flachdetektor-CT als ergänzende Untersuchung bei der endoluminalen Behandlung von thorakalen und abdominellen Aortenaneurysmen - Erste klinische ErfahrungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2007
- Optimal fluoroscopic view selection for percutaneous coronary intervention by multislice computed tomographyInternational Journal of Cardiology, 2007