The Photodetector Array Camera and Spectrometer (PACS) on the HerschelSpace Observatory
- 16 July 2010
- journal article
- letter
- Published by EDP Sciences in Astronomy and Astrophysics
- Vol. 518, L2
- https://doi.org/10.1051/0004-6361/201014535
Abstract
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16×25 pixels, each, and two filled silicon bolometer arrays with 16×32 and 32×64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60–210 μm wavelength regime. In photometry mode, it simultaneously images two bands, 60–85 μm or 85–125 μm and 125–210 μm, over a field of view of ~1.75'× 3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47” × 47”, resolved into 5×5 pixels, with an instantaneous spectral coverage of ~1500 km s-1 and a spectral resolution of ~175 km s-1. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the performance verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions.Keywords
Other Versions
This publication has 26 references indexed in Scilit:
- Neptune's atmospheric composition from AKARI infrared spectroscopyAstronomy and Astrophysics, 2010
- MADmap: A MASSIVELY PARALLEL MAXIMUM LIKELIHOOD COSMIC MICROWAVE BACKGROUND MAP-MAKERThe Astrophysical Journal Supplement Series, 2010
- Herschel flight models sorption coolersCryogenics, 2008
- Proton irradiation of PACS stressed Ge:Ga detector arrays to simulate L2-orbit conditionsPublished by SPIE-Intl Soc Optical Eng ,2006
- Cryogenic far-infrared laser absorptivity measurements of the Herschel Space Observatory telescope mirror coatings.Applied Optics, 2004
- Filled Bolometer Arrays for Herschel/PACSPublished by SPIE-Intl Soc Optical Eng ,2003
- Drizzle: A Method for the Linear Reconstruction of Undersampled ImagesPublications of the Astronomical Society of the Pacific, 2002
- FIRST-PACS: design and performance of the sensor engineering modelsPublished by SPIE-Intl Soc Optical Eng ,2000
- New technological development for far-infrared bolometer arraysPublished by SPIE-Intl Soc Optical Eng ,1999
- A review of frequency measurements of optically pumped lasers from 0.1 to 8 THzJournal of Applied Physics, 1986