Abstract
Mobile and long-term recording of biomedical signals, such as electrocardiogram (ECG), electromyogram (EMG), and EEG, can improve diagnosis and monitor the evolution of several widespread diseases. However, it requires specific solutions, such as wearable devices, that should be particularly comfortable for patients, while at the same time ensuring medical-grade signal acquisition quality, including power line interference (PLI) removal. This paper focuses on the on-board real-time PLI filtering on a low-power biopotential acquisition wearable system. This paper analyzes in depth basic and advanced PLI filtering techniques and evaluates them in a wearable real-time processing scenario, assessing performance on EMG and ECG signals. Our experiments prove that most PLI removal algorithms are not usable in this challenging context, because they lack robustness or they require offline processing and large amounts of available data. On the other hand, adaptive filtering techniques are robust and well suited for lightweight online processing. We substantiate this finding with offline analysis and comparison, as well as with a complete embedded implementation on our low-power low-cost wearable device.Keywords
Funding Information
- Nano-Tera.ch ICYSoC Project through the Swiss Confederation and scientifically evaluated by the Swiss National Science Foundation
- EuroCPS EU Project (644090)
This publication has 30 references indexed in Scilit:
- A Versatile Embedded Platform for EMG Acquisition and Gesture RecognitionIEEE Transactions on Biomedical Circuits and Systems, 2015
- Digitally controlled feedback for DC offset cancellation in a wearable multichannel EMG platformPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2015
- A 345 µW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSPIEEE Journal of Solid-State Circuits, 2014
- A Multichannel EEG Acquisition Scheme Based on Single Ended Amplifiers and Digital DRLIEEE Transactions on Biomedical Circuits and Systems, 2012
- A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG MonitoringIEEE Transactions on Biomedical Circuits and Systems, 2011
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppressionIEEE Transactions on Biomedical Engineering, 1995
- On the adaptive lattice notch filter for the detection of sinusoidsIEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing, 1993
- High-quality recording of bioelectric eventsMedical & Biological Engineering & Computing, 1990
- Design of Digital Notch FiltersIEEE Transactions on Communications, 1974