Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences
Open Access
- 17 April 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (9), 2345-2373
- https://doi.org/10.1088/0031-9155/53/9/010
Abstract
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a widely used technique for assessing tissue physiology. Spoiled gradient echo (SPGR) pulse sequences are one of the most common methods for acquisition of DCE-MRI data, providing high temporal and spatial resolution with strong T(1)-weighting. Conversion of SPGR signal to concentration is briefly reviewed, and a new closed-form expression for concentration measurement uncertainty for finite signal-to-noise ratio (SNR) and baseline scan time is derived. This result is applicable to arbitrary concentration-dependent relaxation rate and is valid over the same domain as the theoretical SPGR signal equation. Expressions for the lower and upper bounds on measurable concentration are also derived. The existence of a concentration- and tissue-dependent optimal flip angle that minimizes concentration uncertainty is demonstrated and it is shown that, for clinically relevant pulse sequence parameters, this optimal flip angle is significantly larger than the corresponding Ernst angle. Analysis of three pulse sequences from the DCE-MRI literature shows that optimization of flip angle using the methods discussed here leads to potential improvements of 10-1166% in effective SNR over the 0.5-5.0 mM concentration range with minimal or no loss of measurement accuracy down to 0.1 mM. In vivo data from three study patients provide further support for our theoretical expression for concentration measurement uncertainty, with predicted and experimental estimates agreeing to within +/- 30%. Equations for concentration bias resulting from biases in flip angle and from pre-contrast relaxation time and contrast relaxivity (both longitudinal and transverse) are also derived in closed-form. The resulting equations show the potential for significant contributions to bias in concentration measurement arising from even relatively small mis-specification of flip angle and/or pre-contrast longitudinal relaxation time, particularly at high contrast concentrations.Keywords
This publication has 31 references indexed in Scilit:
- Effect of magnetic field gradients induced by microvasculature on NMR measurements of molecular self-diffusion in biological tissuesJournal of Magnetic Resonance, 2004
- Assessment of antiangiogenic and antivascular therapeutics using MRI: recommendations for appropriate methodology for clinical trialsThe British Journal of Radiology, 2003
- Variation of the relaxographic “shutter‐speed” for transcytolemmal water exchange affects the CR bolus‐tracking curve shapeMagnetic Resonance in Medicine, 2003
- Determining and optimizing the precision of quantitative measurements of perfusion from dynamic contrast enhanced MRIJournal of Magnetic Resonance Imaging, 2003
- Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady stateMagnetic Resonance in Medicine, 2003
- Uncertainty in the analysis of tracer kinetics using dynamic contrast‐enhanced T1‐weighted MRIMagnetic Resonance in Medicine, 2002
- Physiological noise in oxygenation‐sensitive magnetic resonance imagingMagnetic Resonance in Medicine, 2001
- Gd-DTPA relaxivity depends on macromolecular contentMagnetic Resonance in Medicine, 2000
- Signal‐to‐noise efficiency in magnetic resonance imagingMedical Physics, 1990
- Rapid calculation of T1 using variable flip angle gradient refocused imagingMagnetic Resonance Imaging, 1987