Comparison of the Added Value of Contrast-Enhanced 3D Fluid-Attenuated Inversion Recovery and Magnetization-Prepared Rapid Acquisition of Gradient Echo Sequences in Relation to Conventional Postcontrast T1-Weighted Images for the Evaluation of Leptomeningeal Diseases at 3T
Open Access
- 24 December 2009
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (5), 868-873
- https://doi.org/10.3174/ajnr.a1937
Abstract
BACKGROUND AND PURPOSE: The usefulness of contrast-enhanced 3D T2-FLAIR MR imaging for the evaluation of leptomeningeal diseases has not been systematically investigated. The purpose of this study was to assess the value added by contrast-enhanced 3D T2-FLAIR and MPRAGE sequences to conventional postcontrast T1-weighted images in the evaluation of leptomeningeal diseases. We also undertook in vitro studies in attempts to understand the consequences of our patient study. MATERIALS AND METHODS: Twelve patients with confirmed leptomeningeal diseases underwent postcontrast T1-weighted, MPRAGE, and 3D T2-FLAIR imaging at 3T. Two radiologists independently assessed the presence of additional information on postcontrast 3D MR images compared with postcontrast T1-weighted images. The effect of different Gd concentrations and flow velocities on the signal intensity on 3D T2-FLAIR images was investigated in vitro. RESULTS: According to both reviewers, 3D T2-FLAIR images yielded significantly more information than did MPRAGE images (P < .05 and P < .01, respectively). In the in vitro study, 3D T2-FLAIR was more highly sensitive to low Gd concentrations and less sensitive to high Gd concentrations than were T1-weighted or MPRAGE sequences. On 3D T2-FLAIR sequences, at a flow velocity exceeding 1.0 cm/s, the signal intensity of blood-mimicking fluids at concentrations of 0 and 0.1 mmol/L was as low as at 1.3 mmol/L. CONCLUSIONS: For the depiction of leptomeningeal diseases, postcontrast 3D T2-FLAIR provides more additional information than postcontrast MPRAGE imaging. The superiority of the 3D T2-FLAIR sequence is associated with its high sensitivity to flow.Keywords
This publication has 12 references indexed in Scilit:
- Three-Dimensional Fluid Attenuated Inversion Recovery Imaging With Isotropic Resolution and Nonselective Adiabatic Inversion Provides Improved Three-Dimensional Visualization and Cerebrospinal Fluid Suppression Compared to Two-Dimensional Flair at 3 TeslaInvestigative Radiology, 2008
- Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial resultsEuropean Radiology, 2006
- The Role of Blood-Brain Barrier Permeability in Brain Tumor Imaging and TherapeuticsAmerican Journal of Roentgenology, 2005
- Contrast-enhanced FLAIR in the early diagnosis of infectious meningitisNeuroradiology, 2005
- Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 TEuropean Radiology, 2004
- Suppression of Cerebrospinal Fluid and Blood Flow Artifacts in FLAIR MR Imaging with a Single-Slab Three-dimensional Pulse Sequence: Initial ExperienceRadiology, 2001
- FLAIR MR Imaging for Diagnosing Intracranial Meningeal CarcinomatosisAmerican Journal of Roentgenology, 2001
- Brain: Gadolinium-enhanced Fast Fluid-attenuated Inversion-Recovery MR ImagingRadiology, 1999
- Effect of the rate of gadopentetate dimeglumine administration on abdominal vascular and soft-tissue MR imaging enhancement patterns.Radiology, 1996
- Interactions of Paramagnetic Contrast Agents and the Spin Echo Pulse SequenceInvestigative Radiology, 1988