XANES measurements of the rate of radiation damage to selenomethionine side chains
Open Access
- 15 December 2006
- journal article
- radiation damage
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 14 (1), 51-72
- https://doi.org/10.1107/S0909049506048898
Abstract
The radiation-induced disordering of selenomethionine (SeMet) side chains represents a significant impediment to protein structure solution. Not only does the increased B-factor of these sites result in a serious drop in phasing power, but some sites decay much faster than others in the same unit cell. These radio- labile SeMet side chains decay faster than high-order diffraction spots with dose, making it difficult to detect this kind of damage by inspection of the diffraction pattern. The selenium X-ray absorbance near-edge spectrum (XANES) from samples containing SeMet was found to change significantly after application of X-ray doses of 10-100 MGy. Most notably, the sharp 'white line' feature near the canonical Se edge disappears. The change was attributed to breakage of the C� —Se bond in SeMet. This spectral change was used as a probe to measure the decay rate of SeMet with X-ray dose in cryo-cooled samples. Two protein crystal types and 15 solutions containing free SeMet amino acid were examined. The damage rate was influenced by the chemical and physical condition of the sample, and the half-decaying dose for the selenium XANES signal ranged from 5 to 43 MGy. These decay rates were 34- to 3.8-fold higher than the rate at which the Se atoms interacted directly with X-ray photons, so the damage mechanism must be a secondary effect. Samples that cooled to a more crystalline state generally decayed faster than samples that cooled to an amorphous solid. The single exception was a protein crystal where a nanocrystalline cryoprotectant had a protective effect. Lowering the pH, especially with ascorbic or nitric acids, had a protective effect, and SeMet lifetime increased monotonically with decreasing sample temperature (down to 93 K). The SeMet lifetime in one protein crystal was the same as that of the free amino acid, and the longest SeMet lifetime measured was found in the other protein crystal type. This protection was found to arise from the folded structure of the protein molecule. A mechanism to explain observed decay rates involving the damaging species following the electric field lines around protein molecules is proposed.Keywords
This publication has 40 references indexed in Scilit:
- Will reduced radiation damage occur with very small crystals?Journal of Synchrotron Radiation, 2005
- Parameters affecting the X-ray dose absorbed by macromolecular crystalsJournal of Synchrotron Radiation, 2005
- Two-wavelength MAD phasing and radiation damage: a case studyJournal of Synchrotron Radiation, 2005
- Suite of three protein crystallography beamlines with single superconducting bend magnet as the sourceJournal of Synchrotron Radiation, 2004
- Structural effects of radiation damage and its potential for phasingActa Crystallographica Section D-Biological Crystallography, 2004
- Automated protein crystal structure determination using elvesProceedings of the National Academy of Sciences of the United States of America, 2004
- Ultrahigh Resolution Structure of a Class A β-Lactamase: On the Mechanism and Specificity of the Extended-spectrum SHV-2 EnzymeJournal of Molecular Biology, 2003
- Structural changes in a cryo-cooled protein crystal owing to radiation damageActa Crystallographica Section D-Biological Crystallography, 2000
- Specific chemical and structural damage to proteins produced by synchrotron radiationProceedings of the National Academy of Sciences, 2000
- Towards the measurement of ideal data for macromolecular crystallography using synchrotron sourcesActa Crystallographica Section D-Biological Crystallography, 1993