Terahertz sensing in corneal tissues
Open Access
- 1 January 2011
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (5), 057003-057003-8
- https://doi.org/10.1117/1.3575168
Abstract
This work introduces the potential application of terahertz (THz) sensing to the field of ophthalmology, where it is uniquely suited due to its nonionizing photon energy and high sensitivity to water content. Reflective THz imaging and spectrometry data are reported on ex-vivo porcine corneas prepared with uniform water concentrations using polyethylene glycol (PEG) solutions. At 79% water concentration by mass, the measured reflectivity of the cornea was 20.4%, 14.7%, 11.7%, 9.6%, and 7.4% at 0.2, 0.4, 0.6, 0.8, and 1 THz, respectively. Comparison of nine corneas hydrated from 79.1% to 91.5% concentration by mass demonstrated an approximately linear relationship between THz reflectivity and water concentration, with a monotonically decreasing slope as the frequency increases. The THz-corneal tissue interaction is simulated with a Bruggeman model with excellent agreement. THz applications to corneal dystrophy, graft rejection, and refractive surgery are examined from the context of these measurements.Keywords
This publication has 35 references indexed in Scilit:
- Corneal Thickness and Endothelial Cell Characteristics in Patients with Myotonic DystrophyOphthalmology, 2010
- Characterization of a planar self-complementary square-spiral antenna in the THz regionMicrowave and Optical Technology Letters, 2006
- Terahertz pulsed imaging of basal cell carcinoma ex vivo and in vivoBritish Journal of Dermatology, 2004
- Terahertz Pulse Imaging of ex vivo Basal Cell CarcinomaJournal of Investigative Dermatology, 2003
- Effective permittivity of mixtures: numerical validation by the FDTD methodIEEE Transactions on Geoscience and Remote Sensing, 2000
- Miscellaneous data on materials for millimetre and submillimetre opticsInternational Journal of Infrared and Millimeter Waves, 1996
- Limited lateral spread of stromal edema in the human cornea fitted with a ('donut') contact lens with a large central apertureCurrent Eye Research, 1988
- Far infrared transmission of dielectrics at cryogenic and room temperatures: glass, Fluorogold, Eccosorb, Stycast, and various plasticsApplied Optics, 1986
- Effective medium models for the optical properties of inhomogeneous materialsApplied Optics, 1981
- Flow of water in the corneal stromaExperimental Eye Research, 1962