Abstract
Background: Mechanical properties and biocompatibility make zirconia ceramics suitable implant material. The characteristics of tooth‐color like, the ability to be machined and the low plaque affinity make zirconia especially suitable as a dental implant material. The influence of surface modification on the osseointegration of this material has not been extensively investigated. Purpose: Long‐term investigations with titanium implants have shown superior biomechanical results with the sandblasted acid‐etched (SLA) surface, demonstrating a high bone–implant interaction. The objective of this study was to compare two different zirconia surface topographies biomechanically and histologically with the well‐documented titanium SLA surface. Material and methods: Zirconia implants with either a machined (ZrO2m) or a sandblasted (rough, ZrO2r) surface were manufactured with the exact same cylindrical shape with a standard ITI thread configuration as the SLA titanium implants. The incisors 2 and 3 were removed from both sides of the maxillae of 13 adult miniature pigs and the tissues left to heal for 6 months. After this time period the animals received a total of 78 implants using a randomized scheme, with the titanium SLA implant used as an only individual reference. After healing periods of 4, 8, and 12 weeks 20, 24, and 25 implants, respectively, were subjected to removal torque tests (RTQ) as the main biomechanical analysis of the of the study. A fewer number was resected on bloc, embedded in methylmethacrylat and analyzed for their direct bone apposition under a light microscope. Results: Surface analysis revealed the highest surface roughness for the SLA‐implant, followed by ZrO2r and ZrO2m. The turned ZrO2m implants showed statistically significant lower RTQ values than the other two implants types after 8 and 12 weeks, while the SLA implant showed significantly higher RTQs values than ZrO2r surface after 8 weeks. Differences in the bone apposition were observed in the histomorphometric analysis using light microscopy for all surfaces at any time point. Conclusion: The findings suggest that ZrO2r implants can achieve a higher stability in bone than ZrO2m implants. Roughening the turned zirconia implants enhances bone apposition and has a beneficial effect on the interfacial shear strength.Keywords
This publication has 13 references indexed in Scilit:
- Loaded Custom‐Made Zirconia and Titanium Implants Show Similar Osseointegration: An Animal ExperimentThe Journal of Periodontology, 2004
- Fracture resistance and reliability of new zirconia postsThe Journal of Prosthetic Dentistry, 2004
- Biomechanical comparison of the sandblasted and acid‐etched and the machined and acid‐etched titanium surface for dental implantsJournal of Biomedical Materials Research, 2002
- Osseointegration of endodontic endosseous conesZirconium oxide vs titaniumOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2000
- In vitro reactions of human osteoblasts in culture with zirconia and alumina ceramicsJournal of Biomedical Materials Research, 1999
- Interface shear strength of titanium implants with a sandblasted and acid-etched surface: A biomechanical study in the maxilla of miniature pigsJournal of Biomedical Materials Research, 1999
- Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years’ function in monkeys: A clinical and histologic studyThe Journal of Prosthetic Dentistry, 1998
- Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants.Clinical Oral Implants Research, 1997
- Bone remodeling around implanted ceramicsJournal of Biomedical Materials Research, 1996
- Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigsJournal of Biomedical Materials Research, 1991