The absent kidney in99Tcm-MAG3 renogram: a dramatic reversible consequence of contrast nephrotoxicity superimposed on renal obstruction

Abstract
99Tcm-mercaptoacetyltriglycine (MAG3) renogram is a robust imaging technique used to delineate upper urinary tract obstruction. The changes observed on the renogram are often reversible on relief of obstruction. We present two cases illustrating the extreme consequence of contrast nephrotoxicity on pre-existing obstructed kidneys. In one case, this led to severe impairment of perfusion and uptake observed on 99Tcm-MAG3 renogram and in the second case virtual non-visualization of the obstructed kidney. Subsequent treatment of obstruction, led to dramatic improvement in renal function. It is important for clinicians, nuclear medicine physicians and radiologists to be aware of the potential of contrast nephrotoxicity in obstructed kidneys.