Improving the effectiveness of routine prenatal screening for major congenital heart defects
Open Access
- 1 October 2002
- Vol. 88 (4), 387-391
- https://doi.org/10.1136/heart.88.4.387
Abstract
Objective: To evaluate the effectiveness of adding outlet views to the four chamber view in routine prenatal ultrasound screening for major congenital heart defects (CHD) as performed by trained sonographers, and to compare the procedure with current practice. Design and setting: Prospective observational study at a London teaching hospital. Participants and methods: 9277 women booked at a single institution (80% had first trimester nuchal translucency measurement) due to have routine fetal cardiac screening using the four chamber and outflow tract views at > 18 weeks of gestation. Main outcome measure: Identification of major CHD in chromosomally normal and abnormal pregnancies antenatally or postnatally. Results: There were 40 abnormalities (4.3/1000), of which 30 were chromosomally normal (3.3/1000). The overall antenatal detection rate was 75% (95% confidence interval (CI) 59% to 87%) and 70% (95% CI 51% to 85%) for euploid pregnancies. Abnormal cardiac views accounted for 70% of all prenatal diagnoses, 30% of which were made at ≤ 18 weeks. The sensitivity of cardiac views during the first scan at > 18 weeks was 52%. Of all patients undergoing nuchal translucency screening, 34 had major CHD, nine with increased nuchal translucency (26.5%). Factors influencing the results of this screening programme were training and audit of operators, adequate equipment for antenatal examination, ease of access, and low threshold for referral to specialised fetal echocardiography. Conclusion: Adding ventricular outlet views to the four chamber assessment of the heart at routine fetal anomaly scans at > 18 weeks is the most effective technique to detect CHD prenatally. The success of such a programme depends on an infrastructure committed to continuous in house training of obstetric ultrasonographers coupled with feedback from specialised fetal cardiologists, as well as adequate resource allocation to obstetric hospitals involved with antenatal screening.Keywords
This publication has 27 references indexed in Scilit:
- Limitations of using first‐trimester nuchal translucency measurement in routine screening for major congenital heart defectsUltrasound in Obstetrics & Gynecology, 2001
- Prenatal diagnosis of congenital heart disease in the northern region of England: benefits of a training programme for obstetric ultrasonographersHeart, 2000
- First-trimester transabdominal fetal echocardiographyThe Lancet, 1998
- Incidence of congenital heart defects in fetuses of diabetic mothers: a retrospective study of 326 casesUltrasound in Obstetrics & Gynecology, 1996
- Fetal heart screening in low‐risk pregnanciesUltrasound in Obstetrics & Gynecology, 1995
- The accuracy of antenatal fetal echocardiography screening in high- and low-risk patientsAmerican Journal of Obstetrics and Gynecology, 1995
- Prenatal detection of heart defects at the routine fetal examination at 18 weeks in a non‐selected populationUltrasound in Obstetrics & Gynecology, 1995
- Familial recurrence of congenital heart disease in a prospective series of mothers referred for fetal echocardiographyThe American Journal of Cardiology, 1986
- Congenital heart disease in a cohort of 19,502 births with long-term follow-upThe American Journal of Cardiology, 1978
- Congenital Heart Disease in 56,109 Births Incidence and Natural HistoryCirculation, 1971