Histologic Evaluation of Implants Following Flapless and Flapped Surgery: A Study in Canines
- 1 October 2006
- journal article
- Published by Wiley in The Journal of Periodontology
- Vol. 77 (10), 1717-1722
- https://doi.org/10.1902/jop.2006.060090
Abstract
Flapless surgery requires penetration of the alveolar mucosa and bone without reflection of mucoperiosteal flaps. Do these techniques force gingival tissue or foreign materials into osteotomies? If so, do such tissues or materials interfere with osseointegration? A proof-of-principle study using a canine model attempted to answer these questions. Five young adult Hound Labrador mongrel dogs received implants with a moderately roughened surface by anodic oxidation using flapless or conventional one-stage (control) surgery in contralateral jaw quadrants. The implants were placed into the osteotomies, and the international stability quotient (ISQ) was recorded using resonance frequency analysis. These measurements were repeated following a 3-month healing interval when the animals were euthanized, and implants and surrounding tissues were retrieved and processed for histologic analysis. The implants were stable upon insertion and demonstrated increased stability at 3 months without significant differences between surgical protocols. The histologic evaluation showed high bone-implant contact (flapless surgery: 54.7% +/- 8.4%; control: 52.2% +/- 13.0%; P >0.05) without evidence of gingival tissue or foreign body inclusions. There were no significant differences in marginal bone levels between the surgical protocols. Post-insertion and at 3 months, ISQ values depended on the amount of torque delivered. Immediately post-insertion, for every 1-unit increase in torque value, the ISQ increased by 0.3 (95% confidence interval: 0.1 to 0.4; P = 0.0043). Three months postoperatively, for every one-unit increase in torque the ISQ value decreased 0.2 (95% confidence interval: -0.4 to -0.1; P = 0.0012). The effect of torque on ISQ values was independent of treatment effects and remained significant after adjustment for treatment. The results suggest that implants placed without flap reflection remain stable and exhibit clinically relevant osseointegration similar to when implants are placed with flapped procedures. Greater torque at implant placement resulted in less implant stability at 3 months.Keywords
This publication has 18 references indexed in Scilit:
- Implant Stability Measurements for Implants Placed at the Time of Extraction: A Cohort, Prospective Clinical TrialThe Journal of Periodontology, 2005
- An immediately loaded CAD/CAM-guided definitive prosthesis: A clinical reportThe Journal of Prosthetic Dentistry, 2005
- Minimally Invasive Radical ProstatectomyMayo Clinic Proceedings, 2004
- Minimally Invasive Radical ProstatectomyMayo Clinic Proceedings, 2004
- Periodontal repair in dogs: effect of recombinant human bone morphogenetic protein‐12 (rhBMP‐12) on regeneration of alveolar bone and periodontal attachmentJournal of Clinical Periodontology, 2004
- Precision of transfer of preoperative planning for oral implants based on cone‐beam CT‐scan images through a robotic drilling machineClinical Oral Implants Research, 2002
- Resonance frequency measurements of implant stability in viva. A cross‐sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.Clinical Oral Implants Research, 1997
- Quantitative determination of the stability of the implant‐tissue interface using resonance frequency analysisClinical Oral Implants Research, 1996
- A method for the study of undecalcified bones and teeth with attached soft tissues*Journal of Oral Pathology & Medicine, 1982