The Physiological Significance of the Time-to-Maximum (Tmax) Parameter in Perfusion MRI
- 31 May 2010
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Stroke
- Vol. 41 (6), 1169-1174
- https://doi.org/10.1161/strokeaha.110.580670
Abstract
Background and Purpose— Many perfusion-related MRI parameters are used to investigate the penumbra in stroke. Although time-to-maximum (Tmax) of the residue function has been suggested as a very promising parameter, its physiological meaning and sensitivity to experimental conditions are not well-understood. Methods— We used simulations to further our understanding of the practical meaning of Tmax and to provide recommendations for its use in clinical investigations. We interpret in vivo examples guided by the simulation findings. Results— Whereas Tmax has several attractive properties for clinical use, it is shown that its physiological interpretation is complex and affected by experimental conditions. Tmax is found to reflect a combination of delay, dispersion, and, to a lesser degree, mean transit time. It should therefore mainly be considered a measure of macrovascular characteristics. Furthermore, based on the simulations, use of temporal-interpolation is highly recommended, as is correction for slice-acquisition timing differences. Conclusion— Special care should be taken when setting-up Tmax thresholds for data acquired with different protocols (eg, multicenter studies) because various factors can influence the measured Tmax. Because of its complementary information, used in conjunction with delay-insensitive cerebral blood-flow, cerebral blood volume, and mean transit time maps, Tmax should provide important additional information on brain hemodynamic status.Keywords
This publication has 16 references indexed in Scilit:
- Optimal Tmax Threshold for Predicting Penumbral Tissue in Acute StrokeStroke, 2009
- Effects of alteplase beyond 3 h after stroke in the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET): a placebo-controlled randomised trialThe Lancet Neurology, 2008
- Magnetic resonance imaging profiles predict clinical response to early reperfusion: The diffusion and perfusion imaging evaluation for understanding stroke evolution (DEFUSE) studyAnnals of Neurology, 2006
- Bolus delay and dispersion in perfusion MRI: Implications for tissue predictor models in strokeMagnetic Resonance in Medicine, 2006
- Refining the Perfusion–Diffusion Mismatch HypothesisStroke, 2005
- Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularizationMagnetic Resonance in Medicine, 2003
- Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decompositionMagnetic Resonance in Medicine, 2000
- Thrombolytic reversal of acute human cerebral ischemic injury shown by diffusion/perfusion magnetic resonance imagingAnnals of Neurology, 2000
- Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging TechniquesJournal of Cerebral Blood Flow & Metabolism, 1999
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996