Dispersion, coherence and noise of Fourier domain mode locked lasers
- 29 May 2009
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (12), 9947-9961
- https://doi.org/10.1364/oe.17.009947
Abstract
We report on the effect of chromatic dispersion on coherence length and noise of Fourier Domain Mode Locked (FDML) lasers. An FDML laser with a sweep range of 100nm around 1550nm has been investigated. Cavity configurations with and without dispersion compensation have been analyzed using different widths of the intra-cavity optical band-pass filter. The measurements are compared to non-FDML wavelength swept laser sources. Based on these observations, a simple model is developed providing a connection between timing, photon cavity lifetime and characteristic time constant of the filter. In an optimized configuration, an instantaneous laser linewidth of 20pm is observed, corresponding to a 10× narrowing compared to the intra-cavity optical band-pass filter. A relative intensity noise of -133dBc/Hz or 0.2% at 100MHz detection bandwidth during sweep operation is observed. For optimum operation, the filter drive frequency has to be set within 2ppm or 120mHz at 51kHz.This publication has 33 references indexed in Scilit:
- High performance wavelength-swept laser with mode-locking technique for optical coherence tomographyOptics Communications, 2009
- Ultrahigh-Speed Optical Coherence Tomography for Three-Dimensional and En Face Imaging of the Retina and Optic Nerve HeadInvestigative Ophthalmology & Visual Science, 2008
- K-space linear Fourier domain mode locked laser and applications for optical coherence tomographyOptics Express, 2008
- High-resolution optical coherence tomography imaging of the living kidneyLaboratory Investigation, 2008
- Three-dimensional endomicroscopy using optical coherence tomographyNature Photonics, 2007
- Comparison of three-dimensional optical coherence tomography and high resolution photography for art conservation studiesOptics Express, 2007
- In vivo high-contrast imaging of deep posterior eye by 1-μm swept source optical coherence tomography and scattering optical coherence angiographyOptics Express, 2007
- Wavelength-agile H2O absorption spectrometer for thermometry of general combustion gasesProceedings of the Combustion Institute, 2007
- Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nmOptics Express, 2005
- Intensity noise and spontaneous emission coupling in superluminescent light sourcesIEEE Journal of Quantum Electronics, 1990