Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy
Open Access
- 10 May 2013
- journal article
- research article
- Published by Springer Science and Business Media LLC in Respiratory Research
- Vol. 14 (1), 1-8
- https://doi.org/10.1186/1465-9921-14-50
Abstract
With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.Keywords
This publication has 33 references indexed in Scilit:
- Complications, Consequences, and Practice Patterns of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration Results of the AQuIRE RegistryChest, 2013
- Diagnosis of Mediastinal Adenopathy—Real-Time Endobronchial Ultrasound Guided Needle Aspiration versus MediastinoscopyJournal of Thoracic Oncology, 2008
- Invasive Mediastinal Staging of Lung CancerChest, 2007
- Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysisThorax, 2005
- American College of Chest Physicians and American Association for Bronchology Consensus StatementChest, 2005
- Real-time Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration of Mediastinal and Hilar Lymph NodesChest, 2004
- Current Concepts in the Mediastinal Lymph Node Staging of Nonsmall Cell Lung CancerAnnals of Surgery, 2003
- Interventional Pulmonary ProceduresChest, 2003
- British Thoracic Society guidelines on diagnostic flexible bronchoscopyThorax, 2001
- The High Price off BronchoscopyChest, 1990