Improved measurement of carbonaceous aerosol: evaluation of the sampling artifacts and inter-comparison of the thermal-optical analysis methods
Open Access
- 10 September 2010
- journal article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 10 (17), 8533-8548
- https://doi.org/10.5194/acp-10-8533-2010
Abstract
The sampling artifacts (both positive and negative) and the influence of thermal-optical methods (both charring correction method and the peak inert mode temperature) on the split of organic carbon (OC) and elemental carbon (EC) were evaluated in Beijing. The positive sampling artifact constituted 10% and 23% of OC concentration determined by the bare quartz filter during winter and summer, respectively. For summer samples, the adsorbed gaseous organics were found to continuously evolve off the filter during the whole inert mode when analyzed by the IMPROVE-A temperature protocol. This may be due to the oxidation of the adsorbed organics during sampling (reaction artifact) which would increase their thermal stability. The backup quartz approach was evaluated by a denuder-based method for assessing the positive artifact. The quartz-quartz (QBQ) in series method was demonstrated to be reliable, since all of the OC collected by QBQ was from originally gaseous organics. Negative artifact that could be adsorbed by quartz filter was negligible. When the activated carbon impregnated glass fiber (CIG) filter was used as the denuded backup filter, the denuder efficiency for removing gaseous organics that could be adsorbed by the CIG filter was only about 30%. EC values were found to differ by a factor of about two depending on the charring correction method. Influence of the peak inert mode temperature was evaluated based on the summer samples. The EC value was found to continuously decrease with the peak inert mode temperature. Premature evolution of light absorbing carbon began when the peak inert mode temperature was increased from 580 to 650 °C; when further increased to 800 °C, the OC and EC split frequently occurred in the He mode, and the last OC peak was characterized by the overlapping of two separate peaks. The discrepancy between EC values defined by different temperature protocols was larger for Beijing carbonaceous aerosol compared with North America and Europe, perhaps due to the higher concentration of brown carbon in Beijing aerosol.This publication has 69 references indexed in Scilit:
- Positive sampling artifact of carbonaceous aerosols and its influence on the thermal-optical split of OC/ECAtmospheric Chemistry and Physics, 2009
- Measurement of semivolatile carbonaceous aerosols and its implications: A reviewEnvironment International, 2009
- Brown Carbon Spheres in East Asian Outflow and Their Optical PropertiesScience, 2008
- Air pollution in mega cities in ChinaAtmospheric Environment, 2008
- Black carbon or brown carbon? The nature of light-absorbing carbonaceous aerosolsAtmospheric Chemistry and Physics, 2006
- Estimating the Secondary Organic Aerosol Contribution to PM2.5Using the EC Tracer Method Special Issue ofAerosol Science and Technologyon Findings from the Fine Particulate Matter Supersites ProgramAerosol Science and Technology, 2004
- Equivalence of Elemental Carbon by Thermal/Optical Reflectance and Transmittance with Different Temperature ProtocolsEnvironmental Science & Technology, 2004
- Comparison of IMPROVE and NIOSH Carbon MeasurementsAerosol Science and Technology, 2001
- Concentration and Composition of Atmospheric Aerosols from the 1995 SEAVS Experiment and a Review of the Closure between Chemical and Gravimetric MeasurementsJournal of the Air & Waste Management Association, 2000
- Problems in the sampling and analysis of carbon particulateAtmospheric Environment (1967), 1983