Determination of serum tetranectin: technical and clinical evaluation of three sandwich immunoassays

Abstract
The performance of two sandwich-type immunoassays for the determination of the tumour marker tetranectin using monoclonal antibodies Hyb 130-13 and 130-14 as catching layer was compared with the performance of a polyclonal assay. Sensitivities were 0.4–0.6 μg/l, and intra- and inter-assay coefficients of variation were PPP<0.05). In sera from patients with ovarian cancer, tetranectin concentrations were lower in the polyclonal assay than in the monoclonal assays. This could, hypothetically, be explained by ligand-binding or other conformational changes in tetranectin, influencing the antigenicity of the molecule.