Precise Quantification of Pressure Flow Waveforms of a Pulsatile Ventricular Assist Device
- 1 January 2005
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in ASAIO Journal
- Vol. 51 (1), 56-59
- https://doi.org/10.1097/01.mat.0000150326.51377.a0
Abstract
Unreliable quantification of flow pulsatility has hampered many efforts to assess the importance of pulsatile perfusion. Generation of pulsatile flow depends upon an energy gradient. It is necessary to quantify pressure flow waveforms in terms of hemodynamic energy levels to make a valid comparison between perfusion modes during chronic support. The objective of this study was to quantify pressure flow waveforms in terms of energy equivalent pressure (EEP) and surplus hemodynamic energy (SHE) levels in an adult mock loop using a pulsatile ventricle assist system (VAD). A 70 cc Pierce-Donachy pneumatic pulsatile VAD was used with a Penn State adult mock loop. The pump flow rate was kept constant at 5 L/min with pump rates of 70 and 80 bpm and mean aortic pressures (MAP) of 80, 90, and 100 mm Hg, respectively. Pump flows were adjusted by varying the systolic pressure, systolic duration, and the diastolic vacuum of the pneumatic drive unit. The aortic pressure was adjusted by varying the systemic resistance of the mock loop were calculated at each experimental stage. The difference between the EEP and the MAP is the extra energy generated by this device. This difference is approximately 10% in a normal human heart. The EEP levels were 88.3 ± 0.9 mm Hg, 98.1 ± 1.3 mm Hg, and 107.4 ± 1.0 mm Hg with a pump rate of 70 bpm and an aortic pressure of 80 mm Hg, 90 mm Hg, and 100 mm Hg, respectively. Surplus hemodynamic energy in terms of ergs/cm3 was 11,039 ± 1,236 ergs/cm3, 10,839 ± 1,659 ergs/cm3, and 9,857 ± 1,289 ergs/cm3, respectively. The percentage change from the mean aortic pressure to EEP was 10.4 ± 1.2 %, 9.0 ± 1.4 %, and 7.4 ± 1.0% at the same experimental stages. Similar results were obtained when the pump rate was changed from 70 bpm to 80 bpm. The EEP and SHE formulas are adequate to quantify different levels of pulsatility for direct and meaningful comparisons. This particular pulsatile VAD system produces near physiologic hemodynamic energy levels at each experimental stage.Keywords
This publication has 11 references indexed in Scilit:
- Microcirculation of the Bulbar Conjunctiva in the Goat Implanted with a Total Artificial Heart: Effects of Pulsatile and Nonpulsatile FlowASAIO Journal, 2004
- How Should Investigators Compare Different Perfusion Modes or Different Types of Pulsatile Flow During Chronic Support?ASAIO Journal, 2004
- Myths and Truths of Pulsatile and Nonpulsatile Perfusion During Acute and Chronic Cardiac SupportArtificial Organs, 2004
- Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device supportThe Annals of Thoracic Surgery, 2004
- Energy equivalent pressure formula is for precise quantification of different perfusion modesThe Annals of Thoracic Surgery, 2003
- Fundamentals of Pulsatile versus Nonpulsatile Flow During Chronic SupportASAIO Journal, 2003
- End-organ function during chronic nonpulsatile circulationThe Annals of Thoracic Surgery, 2002
- The Role of Pulsatility in End-Organ Microcirculation After Cardiogenic ShockASAIO Journal, 1996
- Hemodynamic analysis could resolve the pulsatile blood flow controversyThe Annals of Thoracic Surgery, 1994
- Energy Equivalent PressureArchives of Surgery, 1966