SEM and 3D synchrotron radiation micro‐tomography in the study of bioceramic scaffolds for tissue‐engineering applications
- 6 November 2006
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 97 (3), 638-648
- https://doi.org/10.1002/bit.21249
Abstract
Different biomaterials have been proposed as scaffolds for the delivery of cells and/or biological molecules to repair or regenerate damaged or diseased bone tissues. Particular attention is being given to porous bioceramics that mimic trabecular bone chemistry and structure. Chemical composition, density, pore shape, pore size, and pore interconnection are elements that have to be considered to improve the efficiency of these biomaterials. Commonly, two-dimensional (2D) systems of analysis such as scanning electron microscope (SEM) are used for the characterization and comparison of the scaffolds. Unfortunately, these systems do not allow a complete investigation of the three-dimensional (3D) spatial structure of the scaffold. In this study, we have considered two different techniques, that is, SEM and 3D synchrotron radiation (SR) micro-CT to extract information on the geometry of two hydroxyapatite (HA) bioceramics with identical chemical composition but different micro-porosity, pore size distribution, and pore interconnection pathway. The two scaffolds were obtained with two different procedures: (a) sponge matrix embedding (scaffold FB), and (b) foaming (scaffold EP). Both scaffolds showed structures suitable for tissue-engineering applications, but scaffold EP appeared superior with regard to interconnection of pores, surface on which the new bone could be deposited, and percentage of volume available to bone deposition. Biotechnol. Bioeng. 2007;97: 638–648.Keywords
This publication has 33 references indexed in Scilit:
- Porous scaffold design for tissue engineeringNature Materials, 2005
- Synchrotron Radiation Microtomography of Bone Engineered from Bone Marrow Stromal CellsTissue Engineering, 2004
- Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imagingBiomaterials, 2004
- Quantitative microcomputed tomography analysis of mineralization within three‐dimensional scaffolds in vitroJournal of Biomedical Materials Research Part A, 2004
- Fluorescence Microscopy Imaging of Bone for Automated HistomorphometryTissue Engineering, 2002
- Porous Hydroxyapatite Cell Carrier for Tissue EngineeringKey Engineering Materials, 2000
- Method-Based Differences in the Automated Analysis of the Three-Dimensional Morphology of Trabecular BoneJournal of Bone and Mineral Research, 1997
- Quantification of Bone Microarchitecture with the Structure Model IndexComputer Methods in Biomechanics and Biomedical Engineering, 1997
- Histological and mechanical comparison of hydroxyapatite‐coated cobalt‐chrome and titanium implants in the rabbit femurJournal of Applied Biomaterials, 1995
- Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss.JCI Insight, 1983