Ultrasound measures of muscle thickness: intra‐examiner reliability and influence of body position
- 8 October 2009
- journal article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 29 (6), 440-446
- https://doi.org/10.1111/j.1475-097x.2009.00897.x
Abstract
Ultrasound is an inexpensive and practical alternative to gold standard measures of muscle mass. Changes in body position may lead to intra-muscular fluid shifts that may affect the reliability of ultrasound measures. We assessed test-retest reliability of ultrasound measures of muscle thickness and the effect of position on these measures. Measures of muscle thickness were made from B-mode ultrasound images in 18 healthy participants. Repeated measurements were made by one examiner from two participant positions; standing and recumbent, from 18 anatomical sites. Results demonstrated high test-retest reliability for measures taken in both participant positions [intra-class coefficient (ICC) scores 0.65 to 0.94], except for the recumbent posterior lower leg measures (ICC 0.34). Recumbent measures were significantly smaller than those taken with participants standing. Length of time participants spent lying down did not significantly affect measures, indicating that any changes in intra-muscular fluid related to the time spent recumbent are negligible.Keywords
This publication has 13 references indexed in Scilit:
- Effects of acute supine rest on mid‐thigh cross‐sectional area as measured by computed tomographyClinical Physiology and Functional Imaging, 2007
- Impact of Obesity on Medical Imaging and Image-Guided InterventionAmerican Journal of Roentgenology, 2007
- Validity of Methods Used for the Assessment of Body Components in Children: Pros and Cons of Modern versus Old TechnologyHormone Research in Paediatrics, 2006
- Prediction and validation of total and regional skeletal muscle mass by ultrasound in Japanese adultsEuropean Journal of Applied Physiology, 2005
- Cardiovascular Health and Fitness After StrokeTopics in Stroke Rehabilitation, 2005
- Strength and Muscle Quality in a Well‐Functioning Cohort of Older Adults: The Health, Aging and Body Composition StudyJournal of the American Geriatrics Society, 2003
- Prediction equations for body composition of Japanese adults by B‐mode ultrasoundAmerican Journal of Human Biology, 1994
- Changes in lower limb muscle cross‐sectional area and tissue fluid volume after transition from standing to supineActa Physiologica Scandinavica, 1993
- Quantitation of Muscles and Fat by Ultrasonography: A Useful Method in the Assessment of Malnutrition in ChildrenActa Paediatrica, 1991