On-Line Electrodialytic Salt Removal in Electrospray Ionization Mass Spectrometry of Proteins
- 17 December 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (3), 1015-1021
- https://doi.org/10.1021/ac102809c
Abstract
Salts and buffers, commonly used in isolation and stabilization of biological analytes, have a deleterious effect on electrospray ionization mass spectrometry (ESI-MS). Excessive concentrations of salts lead to ion suppression and adduct formation, which mask or complicate ion signals. In this work, we describe a salt remover (SR), configured as a three-compartment flow-through system, where the central compartment is separated from the outer compartments by a cation-exchange membrane (CEM) and an anion-exchange membrane (AEM). One platinum electrode is placed in each of the outer compartments, where water or electrolyte is flowing. The CEM electrode is held at a negative potential relative to the AEM side; cations/anions migrate by electrophoresis to the CEM/AEM receiver liquids, respectively. Proteins have poorer electrophoretic mobility relative to the buffer components, permitting removal of the salt. The salt-free proteins proceed to the ESI source. The capillary scale SR (internal volume 2.5 μL) described here effectively desalted continuous flows of NaCl solutions (200 mequiv/L at 1 μL/min, equivalent to a flux of 200 nequiv/min with 88% efficiency) and achieved >99.8% salt removal with 154 mM NaCl (isotonic saline) at 1 μL/min. With optimized current, >80% of concurrently present 20 μM protein was transmitted. Desalting efficiency and analyte loss was evaluated with different salt concentration and flow rate combinations under different applied current. Good-quality ESI-MS spectra of cytochrome c, myoglobin, and lysozyme as test proteins in a saline solution, passed through the SR, are demonstrated.Keywords
This publication has 42 references indexed in Scilit:
- Electrospray ionization suppression, a physical or a chemical phenomenon?Biomedical Chromatography, 2005
- Buffer Loading for Counteracting Metal Salt-Induced Signal Suppression in Electrospray IonizationAnalytical Chemistry, 2004
- A study of ion suppression effects in electrospray ionization from mobile phase additives and solid‐phase extractsRapid Communications in Mass Spectrometry, 2003
- Practical implications of some recent studies in electrospray ionization fundamentalsMass Spectrometry Reviews, 2001
- Direct coupling of ionic high-performance liquid chromatography with electrospray ionization mass spectrometry utilizing a microdialysis junction interfaceJournal of Chromatography A, 1999
- In-Trap Cleanup of Proteins from Electrospray Ionization Using Soft Sustained Off-Resonance Irradiation with Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 1998
- Rapid Sequencing of Oligonucleotides by High-Resolution Mass SpectrometryJournal of the American Chemical Society, 1994
- Electrospray Ionization for Mass Spectrometry of Large BiomoleculesScience, 1989
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1988