Filtering in SPECT Image Reconstruction
Open Access
- 23 June 2011
- journal article
- review article
- Published by Hindawi Limited in International Journal of Biomedical Imaging
- Vol. 2011, 1-14
- https://doi.org/10.1155/2011/693795
Abstract
Single photon emission computed tomography (SPECT) imaging is widely implemented in nuclear medicine as its clinical role in the diagnosis and management of several diseases is, many times, very helpful (e.g., myocardium perfusion imaging). The quality of SPECT images are degraded by several factors such as noise because of the limited number of counts, attenuation, or scatter of photons. Image filtering is necessary to compensate these effects and, therefore, to improve image quality. The goal of filtering in tomographic images is to suppress statistical noise and simultaneously to preserve spatial resolution and contrast. The aim of this work is to describe the most widely used filters in SPECT applications and how these affect the image quality. The choice of the filter type, the cut-off frequency and the order is a major problem in clinical routine. In many clinical cases, information for specific parameters is not provided, and findings cannot be extrapolated to other similar SPECT imaging applications. A literature review for the determination of the mostly used filters in cardiac, brain, bone, liver, kidneys, and thyroid applications is also presented. As resulting from the overview, no filter is perfect, and the selection of the proper filters, most of the times, is done empirically. The standardization of image-processing results may limit the filter types for each SPECT examination to certain few filters and some of their parameters. Standardization, also, helps in reducing image processing time, as the filters and their parameters must be standardised before being put to clinical use. Commercial reconstruction software selections lead to comparable results interdepartmentally. The manufacturers normally supply default filters/parameters, but these may not be relevant in various clinical situations. After proper standardisation, it is possible to use many suitable filters or one optimal filter.Keywords
This publication has 34 references indexed in Scilit:
- Comparison of V/Q SPECT and planar V/Q lung scintigraphy in diagnosing acute pulmonary embolismNuclear Medicine Communications, 2010
- Comparison of Different Types of Commercial Filtered Backprojection and Ordered-Subset Expectation Maximization SPECT Reconstruction SoftwareJournal of Nuclear Medicine Technology, 2009
- Comparison of 99mTc-DMSA Dual-Head SPECT Versus High-Resolution Parallel-Hole Planar Imaging for the Detection of Renal Cortical DefectsAmerican Journal of Roentgenology, 2009
- A Comparison Between 3D OSEM and FBP Image Reconstruction Algorithms in SPECTPublished by Springer Science and Business Media LLC ,2009
- Reinventing ventilation/perfusion lung scanning with SPECTNuclear Medicine Communications, 2008
- Usefulness of Tomographic Versus Planar Lung Scintigraphy in Suspected Pulmonary Embolism in a Daily PracticeThe Open Medical Imaging Journal, 2008
- Scatter and Blurring Compensation in Inhomogeneous Media Using a Postprocessing MethodInternational Journal of Biomedical Imaging, 2008
- Gaussian prefiltering of123I DAT SPECT images when using depth-independent resolution recoveryPhysics in Medicine & Biology, 2007
- Isotropic Reconstruction of SPECT Data Using OSEM3D: Correlation with CTAcademic Radiology, 2006
- Quantitative SPECT of DMSA uptake by the kidneys: Assessment of reproducibility: Technical NoteKidney International, 1997