Airborne Contamination Control through Directed Airflow in the Exam Room: A Pilot Study Using a Membrane Diffuser
Open Access
- 1 October 2010
- journal article
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 1 (4), 655-674
- https://doi.org/10.1260/2040-2295.1.4.655
Abstract
Airborne infections have been documented as a major source of hospital acquired infection - one of the major concerns in healthcare delivery. An important factor contributing to airborne infection is cross contamination through air particulate dispersion as affected by the ventilation system design. Clean room technology (with membrane ceiling) has been successfully used in technology and pharmaceutical industries to control airborne contamination. This study examined the performance of membrane ceiling technology in controlling air particulate dispersion in a mock-up exam room. It included both performance tests in a mock-up room and a simulation study of six different ventilation system designs using Computational Fluid Dynamics (CFD) analysis. Findings suggest that a membrane diffuser directed airflow ventilation strategy occupying approximately 20% to 30% of the ceiling surface and placed over the patient in a contemporary sized exam room provides a less turbulent airflow pattern and less mixing of the air between the patient and others in the room.Keywords
This publication has 24 references indexed in Scilit:
- Control of Construction-Associated Nosocomial Aspergillosis in an Antiquated Hematology UnitInfection Control & Hospital Epidemiology, 1996
- An unusual source for an outbreak of methicillin-resistant Staphylococcus aureus on an intensive therapy unitJournal of Hospital Infection, 1996
- Risk of airborne transmission in an operating theatre containing four ultraclean air unitsJournal of Hospital Infection, 1995
- Airborne Fungal Spore Monitoring in a Protective Environment During Hospital Construction, and Correlation with an Outbreak of Invasive AspergillosisInfection Control & Hospital Epidemiology, 1994
- Aspergillus endocarditis after open heart surgery: an epidemiological investigationJournal of Hospital Infection, 1990
- Control of an outbreak of nosocomial aspergillosis by laminar air-flow isolationJournal of Hospital Infection, 1989
- Measurement of bacterial and fungal air counts in two bone marrow transplant unitsJournal of Hospital Infection, 1989
- Invasive aspergillus infection: possible non-ward common source within the hospital environmentJournal of Hospital Infection, 1989
- Efficacy of Infection Control Measures During a Nosocomial Outbreak of Disseminated Aspergillosis Associated with Hospital ConstructionThe Journal of Infectious Diseases, 1986
- Investigation of cross-infection in isolation wards of different designEpidemiology and Infection, 1976