Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm
Top Cited Papers
- 16 October 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 53 (11), 2387-2396
- https://doi.org/10.1109/tbme.2006.880883
Abstract
Exoskeleton robots are promising assistive/rehabilitative devices that can help people with force deficits or allow the recovery of patients who have suffered from pathologies such as stroke. The key component that allows the user to control the exoskeleton is the human machine interface (HMI). Setting the HMI at the neuro-muscular level may lead to seamless integration and intuitive control of the exoskeleton arm as a natural extension of the human body. At the core of the exoskeleton HMI there is a model of the human muscle, the "myoprocessor," running in real-time and in parallel to the physiological muscle, that predicts joint torques as a function of the joint kinematics and neural activation levels. This paper presents the development of myoprocessors for the upper limb based on the Hill phenomenological muscle model. Genetic algorithms are used to optimize the internal parameters of the myoprocessors utilizing an experimental database that provides inputs to the model and allows for performance assessment. The results indicate high correlation between joint moment predictions of the model and the measured data. Consequently, the myoprocessor seems an adequate model, sufficiently robust for further integration into the exoskeleton control systemKeywords
This publication has 30 references indexed in Scilit:
- Connecting cortex to machines: recent advances in brain interfacesNature Neuroscience, 2002
- The Obstacle-Set Method for Representing Muscle Paths in Musculoskeletal ModelsComputer Methods in Biomechanics and Biomedical Engineering, 2000
- Performances of Hill-Type and Neural Network Muscle Models—Toward a Myosignal-Based ExoskeletonComputers and Biomedical Research, 1999
- A Kinematic Model of the Upper Limb Based on the Visible Human Project (VHP) Image DatasetComputer Methods in Biomechanics and Biomedical Engineering, 1999
- The human power amplifier technology at the University of California, BerkeleyRobotics and Autonomous Systems, 1996
- Maximumisometric moments generated by the wrist muscles in flexion-extension and radial-ulnar deviationJournal of Biomechanics, 1996
- A dynamic model for simulating movements of the elbow, forearm, and wristJournal of Biomechanics, 1996
- Human wrist motors: Biomechanical design and application to tendon transfersJournal of Biomechanics, 1996
- Variation of muscle moment arms with elbow and forearm positionJournal of Biomechanics, 1995